Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213811 DEA: 112T2184 EFIS: 1116000174
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-R38.4/R47.3
Work Description: (Alternative Delivery) Construct HOV lanes, soundwalls, culvert rehab, ITS, and bike trail on I-5 . NCC I-5 Highway Improvement.
Location Description: IN SAN DIEGO COUNTY IN ENCINITAS AND CARLSBAD FROM SAN ELIJO LAGOON BRIDGE TO 0.3 MILE NORTH OF PALOMAR AIRPORT ROAD OVERCROSSING.
Contractor Name: Flatiron-Skanska-Stacy and Witbeck, a Joint Venture
Contractor Address: 1525 Faraday Ave. #180, Carlsbad, CA 92008
Resident Engineer: Yong Pak Structure Rep.: Cailyn Le
DIME Sample ID: 2022-03-07-6
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/07/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/08/2022
The quantity of what the sample constitutes: 3 bags, 12 boxes, 3 cans
A brief description of the sample: 1/2" HMA-A
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
DIME Test ID: 2022-03-07-6-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/29/2024
Date Tested: 03/11/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 2T2184 2022-03-07-6-1
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
no data
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
no data
|
|
Mass of HMA Sample prior to ignition
|
1560.3 g
|
|
Corrected Asphalt Binder Content
|
5.41 %
|
|
Mass Loss
|
no data
|
|
Mass of aggregate remaining after ignition
|
1466.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.63 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data
|
|
Test Temperature
|
538 F
|
DIME Test ID: 2022-03-07-6-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/29/2024
Date Tested: 03/10/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 2022-03-07-6-2 0523-PSU 11-2T2184
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7361.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1594.9 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8320.8 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.509
|
|
Theoretical maximum density at 25°C (77°F)
|
no data
|
DIME Test ID: 2022-03-07-6-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/29/2024
Date Tested: 03/10/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 0523-PSU 2022-03-07-9-3 11-2T2184
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
2.8 %
|
|
Percent Air Voids 2
|
2.5
|
|
Percent Air Voids 3
|
2.5
|
|
Average Percent Air Voids
|
2.6
|
DIME Test ID: 2022-03-07-6-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/29/2024
Date Tested: 03/10/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 0523-PSU 2T2184 2022-03-07-06-4
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.439
|
|
Bulk Specific Gravity 2
|
2.446
|
|
Bulk Specific Gravity 3
|
2.447
|
|
Average Bulk Specific Gravity
|
2.444
|
DIME Test ID: 2022-03-07-6-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 08/29/2024
Date Tested: 03/16/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 0523-PSU 11-2T2184
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
209 psi
|
|
Average Wet Tensile Strength
|
165 psi
|
|
Tensile Strength Ratio
|
79
|
DIME Test ID: 2022-03-07-6-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/29/2024
Date Tested: 03/11/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Oil Content Ignition Burn for RAP 0523-PSU 11-2T2184 2022-03-07-6-7
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
no data
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
no data
|
|
Mass of HMA Sample prior to ignition
|
1560.3 g
|
|
Corrected Asphalt Binder Content
|
5.41 %
|
|
Mass Loss
|
no data
|
|
Mass of aggregate remaining after ignition
|
1466.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.63 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data
|
|
Test Temperature
|
538 F
|