Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030H10U4 Cty SAC Rte 5 PM 9.7/24.9 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Daniel Tecle |
Date Reported: |
03/24/2022 |
|
|
Address: |
TL Number: |
293127 |
||
|
City: |
||||
|
Project Name: |
||||
|
Prime Contractor: NOR CAL PAVING TEICHERT/GRANITE |
||||
|
Sample Taken Date: |
02/24/2022 |
Mix Design: |
1613820 |
|
|
Contractor: Unknown |
Location : Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
|||
|
Structure unique identifier: |
||||
|
Structure name: |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.02 | 12.69 | 77693 | 6121.0 | 4 |
| 2 | 4.01 | 12.63 | 75932 | 6012.0 | 4 |
| 3 | 4.02 | 12.69 | 83880 | 6609 | 4 |
DIME Test ID: 2022-02-24-14-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 6250
Age of specimen: 28 days
Certified By: Spencer Adams
|
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing