Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214524 DEA: 07304504 EFIS: 0714000067
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-57-R0.0/R4.5
Work Description: CONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK.
Location Description: LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION
Contractor Name: Griffith Company
Contractor Address: 3050 E. Birch Street, Brea, CA 92821
Resident Engineer: Martin Sandoval Structure Rep.: Avtar Bains
DIME Sample ID: 2022-01-30-8
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 01/30/2022
Date that the sample was received by the laboratory/organization performing the testing: 01/31/2022
The quantity of what the sample constitutes: 10 CY
A brief description of the sample: Concrete Beams
From where was the sample collected: Job Site
Laboratory sample identification: 22-156
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Griffith/Vanguard
The concrete mix design number: 690HEX12
The truck number from where the sample was collected: 3
The batch plant ticket number from where the sample was collected: 3
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Loader
Where the material sample would have been placed if not sampled: NB57 Lane 5
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-01-30-8-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 02/14/2022
Date Tested: 02/09/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of specimens
|
3
|
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
|
Fracture occurred at a capped section
|
No
|
|
Is a beam dimensional correction factor used?
|
No
|
|
Age of specimen
|
10 days
|
|
Modulus of rupture
|
690 psi
|
|
Modulus of rupture 2
|
700 psi
|
|
Modulus of rupture average
|
680 psi
|
|
Modulus of rupture 3
|
650 psi
|