Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 034H9504 Cty SAC Rte 12 PM 0-0.4/26.3-26.4, Var, various Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Masoud Saed |
Date Reported: |
03/03/2022 |
|
|
Address: |
TL Number: |
849209 |
||
|
City: |
||||
|
Project Name: NOTE THIS EA HAS BEEN CLOSED. A NEW EA HAS BEEN OPENED TO COMPLETE THE WORK SEE EA 03-1N0104 FOR CONTINUED WORK ACTIVITIES. |
||||
|
Prime Contractor: Golden State Bridge |
||||
|
Sample Taken Date: |
02/03/2022 |
Mix Design: |
Unknown |
|
|
Contractor: Unknown |
Location : In Sacramento County at four bridges. |
|||
|
Structure unique identifier: |
||||
|
Structure name: |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.04 | 12.82 | 76599 | 5975.0 | 1 |
| 2 | 4.03 | 12.76 | 77048 | 6040.0 | 1 |
DIME Test ID: 2022-02-03-6-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6010
Age of specimen: 28 days
Certified By: Spencer Adams
|
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing