Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2022-01-24-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 01/24/2022
Date that the sample was received by the laboratory/organization performing the testing: 01/28/2022
The quantity of what the sample constitutes: 2 each production lots
A brief description of the sample: #8 epoxy coated rebar
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Coatings Inc
Rebar Heat Number(s): 1202032653
Rebar Epoxy Batch Number(s): XB44501NA
Rebar Coating Specification: ASTM A775
Rebar Size (#): 8
Rebar Coating Color: Green
Rebar Manufacturer: Nucor
Rebar Coater: Western Coatings
Rebar Powder Manufacturer: AkzoNobel
Release Number:
Quality Assurance Code:
DIME Test ID: 2022-01-24-1-1
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 02/08/2022
Date Tested: 02/02/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
no data0
|
Total Length
|
5
|
Holidays Per Linear Foot of Bar
|
no data0 holiday per ft
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|
DIME Test ID: 2022-01-24-1-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 02/08/2022
Date Tested: 02/02/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
8.5
|
Second Bar Mean
|
9.47
|
Lower spec. limit LSL
|
7
|
Upper spec. limit USL
|
16
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
Total mean value
|
8.98
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|