Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213811 DEA: 112T2184 EFIS: 1116000174
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-R38.4/R47.3
Work Description: (Alternative Delivery) Construct HOV lanes, soundwalls, culvert rehab, ITS, and bike trail on I-5 . NCC I-5 Highway Improvement.
Location Description: IN SAN DIEGO COUNTY IN ENCINITAS AND CARLSBAD FROM SAN ELIJO LAGOON BRIDGE TO 0.3 MILE NORTH OF PALOMAR AIRPORT ROAD OVERCROSSING.
Contractor Name: Flatiron-Skanska-Stacy and Witbeck, a Joint Venture
Contractor Address: 1525 Faraday Ave. #180, Carlsbad, CA 92008
Resident Engineer: Yong Pak Structure Rep.: Cailyn Le
DIME Sample ID: 2022-01-13-10
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/13/2022
Date that the sample was received by the laboratory/organization performing the testing: 01/14/2022
The quantity of what the sample constitutes: 12 Boxes, 3 bags, 2 cans
A brief description of the sample: 1/2" HMA PSU
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
DIME Test ID: 2022-01-13-10-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/29/2024
Date Tested: 01/18/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Pass
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
no data
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
no data
|
|
Mass of HMA Sample prior to ignition
|
1597.6 g
|
|
Corrected Asphalt Binder Content
|
5.57 %
|
|
Mass Loss
|
no data
|
|
Mass of aggregate remaining after ignition
|
1501.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.43 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data
|
|
Test Temperature
|
538 F
|
DIME Test ID: 2022-01-13-10-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/29/2024
Date Tested: 01/20/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Pass
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Water
|
|
Specific Gravity for Sample 1
|
2.518
|
|
Theoretical maximum density at 25°C (77°F)
|
no data
|
DIME Test ID: 2022-01-13-10-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/29/2024
Date Tested: 01/18/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Pass
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
4.8 %
|
|
Percent Air Voids 2
|
4.9 %
|
|
Percent Air Voids 3
|
5.1 %
|
|
Average Percent Air Voids
|
4.9 %
|
DIME Test ID: 2022-01-13-10-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/29/2024
Date Tested: 01/18/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 0519-PSU 2T2184 2022-01-13-10-4
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.397
|
|
Bulk Specific Gravity 2
|
2.394
|
|
Bulk Specific Gravity 3
|
2.389
|
|
Average Bulk Specific Gravity
|
2.393
|
DIME Test ID: 2022-01-13-10-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 08/29/2024
Date Tested: 01/26/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 0519-PSU 2T2184 2022-01-13-10
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
9611 psi
|
|
Average Wet Tensile Strength
|
5878 psi
|
|
Tensile Strength Ratio
|
0.61
|
DIME Test ID: 2022-01-13-10-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/29/2024
Date Tested: 01/20/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Oil Content for RAP
Test Result Compliance:
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
no data
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
no data
|
|
Mass of HMA Sample prior to ignition
|
1514.4 g
|
|
Corrected Asphalt Binder Content
|
7.86 %
|
|
Mass Loss
|
no data
|
|
Mass of aggregate remaining after ignition
|
1395.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data
|
|
Test Temperature
|
535.9 F
|
DIME Test ID: 2022-01-13-10-8
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/29/2024
Date Tested: 01/19/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Pass
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
no data
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
no data
|
|
Mass of HMA Sample prior to ignition
|
1558.2 g
|
|
Corrected Asphalt Binder Content
|
5.42 %
|
|
Mass Loss
|
no data
|
|
Mass of aggregate remaining after ignition
|
1467.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.43 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data
|
|
Test Temperature
|
538 F
|