Print Report | Back to Sample Detail

Sample Record for 2021-12-22-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215109 DEA: 081C8504 EFIS: 0813000047 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-0.0/5.8
Work Description: ROADWAY EXCAVATION, HOT MIX ASPHALT, AND STRUCTURAL SHOTCRETE WALLS.
Location Description: RIVERSIDE COUNTY NEAR LAKE ELSINORE FROM ORANGE COUNTY LINE TO MONTE VISTA STREET
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 38000 MONROE STREET, INDIO, CA 92203
Resident Engineer: Osama Abdalla Structure Rep.: Ryan Kash (Reports)

Sample Information

DIME Sample ID: 2021-12-22-15
TL Number from the TL Form:
Sample Submitted By Organization: Jensen Precast - Fontana
Sample Organization Contact: 9096095937
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 12/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 12/22/2021
The quantity of what the sample constitutes: 4 cylinders
A brief description of the sample: 6"x12" concrete samples
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier: 08-1C8504 33 Riv
Structure name: RTA Ortega Highway
The fabricator/manufacturer/facility name: Jensen Precast

Material Information

The concrete mix design number: 10
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 54531
Concrete batch plant: Jensen Fontana
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Conveyor belt
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2021-12-22-15-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 01/19/2022
Date Tested: 12/22/2021
Submitted By Organization: Jensen Precast - Fontana
Organization Address: 14221 San Bernardino Ave,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92335
Organization Email: avali@jensenprecast.com
Organization Phone: (909) 609-5937
General Comments for this Test: 2 Samples tested at 7 days and two tested at 28 days. 28 day average = 7119 psi. Designed Compressive Strength = 6000 psi @ 28 days.
Test Result Compliance:
Additional Comments When Verified: Results for Cast Date 12-22-21
Unit system used? US Units
Number of specimens 4
Test performed With no density determined
Capped in accordance with? no data
Apparent mass of submerged cylinder 1 30 lb
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Average diameter of cylinder 3 6.00 in
Average diameter of cylinder 4 6.00 in
Cross sectional area of cylinder 1 3 in^2
Cross sectional area of cylinder 2 3 in^2
Cross sectional area of cylinder 3 3 in^2
Cross sectional area of cylinder 4 3 in^2
Compressive strength (to nearest 10 psi) 6000 psi
Maximum load on cylinder 1 186654 lb
Maximum load on cylinder 2 190403 lb
Maximum load on cylinder 3 198770 lb
Maximum load on cylinder 4 203770 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Type of fracture pattern of cylinder 4 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Correction factor for cylinder 4 1
Age of specimen 7 days
Age of specimen in hours 168 hours
Serial number of delivery ticket, if available no data