DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 040120T4 Cty SF Rte 80 PM 12.6/13.9 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Tom Larwin |
Date Reported: |
10/20/2014 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: CONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES |
||||
Prime Contractor: CALIFORNIA ENGINEERING CONTRACTORS, INC. |
||||
Sample Taken Date: |
10/03/2014 |
Mix Design: |
D101C5E1 |
|
Contractor: Unknown |
Location : THE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL |
|||
Structure unique identifier: Bent 41A Column |
||||
Structure name: West Tie In Edge Beam |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.18 | 5.99 | 3521.8 | 99243 | 1 |
2 | 28.09 | 5.98 | 3632.1 | 102027 | 1 |
DIME Test ID: 2014-10-03-1-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3580
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 11 days
Certified By: Mike Mullins
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.09 | 5.98 | 4116.9 | 115643 | 1 |
2 | 28.37 | 6.01 | 4187.9 | 118811 | 1 |
DIME Test ID: 2014-10-03-1-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4150
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 17 days
Certified By: Steve Wake
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.09 | 5.98 | 3860.9 | 108453 | 1 |
2 | 28.18 | 5.99 | 3698.3 | 104218 | 1 |
DIME Test ID: 2014-10-03-1-3
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3780
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 14 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |