Print Report | Back to Sample Detail

Sample Record for 2014-07-09-12301252

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 7780 DEA: 112T1824 EFIS: 1100020051 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-4.7/5.6
Work Description: REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location Description: SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real #200, Carlsbad, CA 92008
Resident Engineer: Tom Davis Structure Rep.: Anh Ma

Sample Information

DIME Sample ID: 2014-07-09-12301252
TL Number from the TL Form:
Sample Submitted By Organization: Vulcan Materials Company - San Diego
Sample Organization Contact: (619) 572-9564
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 07/09/2014
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 5 cylinders
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Mission Valley

Material Information

The concrete mix design number: 103612F
The truck number from where the sample was collected: 447
The batch plant ticket number from where the sample was collected: 120777
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: RW299
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 6

DIME Test ID: 2014-07-09-12301252-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 10/03/2014
Date Tested: 07/16/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Compressive strength of cylinder (to nearest 10 psi) 2670 psi
Average diameter of cylinder 1 6.00 in
Maximum load on cylinder 1 75470 lb
Type of fracture pattern of cylinder 1 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 7 days

Test 2 of 6

DIME Test ID: 2014-07-09-12301252-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 10/03/2014
Date Tested: 07/23/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Compressive strength of cylinder (to nearest 10 psi) 2870 psi
Average diameter of cylinder 1 6.00 in
Maximum load on cylinder 1 81060 lb
Type of fracture pattern of cylinder 1 6
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 14 days

Test 3 of 6

DIME Test ID: 2014-07-09-12301252-3
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 10/03/2014
Date Tested: 08/06/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Cross sectional area of cylinder 1 28.274 in^2
Cross sectional area of cylinder 2 28.274 in^2
Capped in accordance with? ASTM C617/CTM521
Compressive strength (to nearest 10 psi) 4100 psi
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Maximum load on cylinder 1 114730 lb
Maximum load on cylinder 2 116780 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 28 days

Test 4 of 6

DIME Test ID: 2014-07-09-12301252-4
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 10/03/2014
Date Tested: 09/03/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Compressive strength of cylinder (to nearest 10 psi) 4980 psi
Average diameter of cylinder 1 6.00 in
Maximum load on cylinder 1 140800 lb
Type of fracture pattern of cylinder 1 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 56 days

Test 5 of 6

DIME Test ID: 2014-07-09-12301252-5
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 10/03/2014
Date Tested: 07/09/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 82 F

Test 6 of 6

DIME Test ID: 2014-07-09-12301252-6
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 10/03/2014
Date Tested: 07/09/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 4.5 inch