Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215083 DEA: 07307504 EFIS: 0714000217
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-101-11.8/31.1
Work Description: PLACE RHMA-G, MODIFY RAMP METERING AND SIGNAL AND LIGHTING SYSTEMS.
Location Description: LOS ANGELES COUNTY FROM TUJUNGA AVENUE UNDERCROSSING TO LAS VIRGENES ROAD OVERCROSSING
Contractor Name: Alfaro Communication
Contractor Address: 15614 South Atlantic Avenue, Compton, CA 90221
Resident Engineer: Arturo Lao Structure Rep.: Unknown
DIME Sample ID: 2021-10-22-21
TL Number from the TL Form: C007156
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Department Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 10/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/28/2021
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan-Sun Valley
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2021-10-22-21-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 11/03/2021
Date Tested: 10/29/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
ASTM Thermometer used?
|
C
|
|
Softening Point Sample 1
|
55 C
|
|
Softening Point Sample 2
|
56 C
|
|
Bath Liquid
|
freshly boiled distilled water
|
|
Minutes Reaction
|
no data
|
DIME Test ID: 2021-10-22-21-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 11/03/2021
Date Tested: 11/01/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Determination
|
Unworked Penetration
|
|
Unworked Penetration
|
26 0.1 mm
|
DIME Test ID: 2021-10-22-21-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 11/03/2021
Date Tested: 11/01/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Temperature
|
25 C
|
|
Ball Penetration (P1)
|
1 mm
|
|
Final Dial reading (F1)
|
72 mm
|
|
Ball Penetration (P2)
|
no data0 mm
|
|
Final Dial reading (F2)
|
70 mm
|
|
Ball Penetration (P3)
|
no data0 mm
|
|
Final Dial reading (F3)
|
70 mm
|
|
Resilience 1
|
29 %
|
|
Resilience 2
|
30 %
|
|
Resilience 3
|
30 %
|
|
Average Resilience
|
30 %
|
|
Minutes Reaction
|
no data
|