Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215556 DEA: 081L6504 EFIS: 0820000131
QA Service Level: 1
DIST-CO-RTE-PM: 08--,58-
Work Description:
Location Description:
Contractor Name: FEC Future Contractors & Engineers, Inc
Contractor Address: 184 Technology Dr., Ste 2, Irvine, CA 92618
Resident Engineer: Larry Canuti Structure Rep.: Unknown
DIME Sample ID: 2021-10-06-35
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Sample Organization Contact: (760) 252-9216
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/06/2021
Date that the sample was received by the laboratory/organization performing the testing: 11/06/2021
The quantity of what the sample constitutes: 6
A brief description of the sample: PCC Rapid set beams
From where was the sample collected: Job Site
Laboratory sample identification: 10062021-SET NO 2
Structure unique identifier:
Structure name: RTE 58 WB LN 2 PM 12 dot 1
The fabricator/manufacturer/facility name: FEC
The concrete mix design number: SM446BR2
The truck number from where the sample was collected: NA
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: AT THE JOB SITE
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2021-10-06-35-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 11/01/2021
Date Tested: 10/06/2021
Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: kaushalkumar.talati@dot.ca.gov
Organization Phone: (951) 840-8328
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens
|
3
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
Fracture occurred at a capped section
|
Yes
|
Is a beam dimensional correction factor used?
|
No
|
Age of specimen
|
no data0 days
|
Modulus of rupture
|
430 psi
|
Modulus of rupture 2
|
420 psi
|
Modulus of rupture average
|
440 psi
|
Modulus of rupture 3
|
470 psi
|
DIME Test ID: 2021-10-06-35-2
Test Method: ASTM C293-10: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam With Center-Point Loading)
Verified Date: 11/01/2021
Date Tested: 10/16/2021
Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: kaushalkumar.talati@dot.ca.gov
Organization Phone: (951) 840-8328
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Modulus of rupture
|
770 psi
|
DIME Test ID: 2021-10-06-35-3
Test Method: ASTM C293-10: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam With Center-Point Loading)
Verified Date: 11/01/2021
Date Tested: 10/16/2021
Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: kaushalkumar.talati@dot.ca.gov
Organization Phone: (951) 840-8328
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Modulus of rupture
|
750 psi
|
DIME Test ID: 2021-10-06-35-4
Test Method: ASTM C293-10: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam With Center-Point Loading)
Verified Date: 11/01/2021
Date Tested: 10/16/2021
Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: kaushalkumar.talati@dot.ca.gov
Organization Phone: (951) 840-8328
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Modulus of rupture
|
770 psi
|