Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215753 DEA: 050N72U4 EFIS: 0520000169
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-4.4/R7.7
Work Description: Please cc Office Engineer Ni Nyoman Paul on reports sent to RE and SR. Construct High Occupancy Vehicle (HOV) lanes on U.S. Route 101 and rehabilitation - Segment 4B.
Location Description: 101 freeway in Summerland, CA
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5335 Debbie Road, Santa Barbara, CA 93111
Resident Engineer: Luobao Cai Structure Rep.: Emiliano Berntsen
DIME Sample ID: 2021-10-27-1
TL Number from the TL Form:
Sample Submitted By Organization: Con-Fab California, LLC
Sample Organization Contact: (661) 630-7162
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/27/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/28/2021
The quantity of what the sample constitutes: One box girder
A brief description of the sample: PCC
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name: Arroyo Paredon Bridge
The fabricator/manufacturer/facility name: Con-Fab California, LLC
The concrete mix design number: SCC-S95-0F
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1879
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of truck chute
Where the material sample would have been placed if not sampled: box girder
From Lot No.:
Bag Lot No.:
DIME Test ID: 2021-10-27-1-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 10/28/2021
Date Tested: 10/27/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2021-10-27-1-2
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 10/28/2021
Date Tested: 10/27/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample
|
Box Girder
|
Volume of the measure
|
0.25 ft^3
|
Density of concrete
|
150.7 lb/ft^3
|
Yield of concrete
|
no data
|
Relative yield of the batch
|
no data
|
Cement content
|
no data
|
Air content
|
no data
|
DIME Test ID: 2021-10-27-1-3
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 10/28/2021
Date Tested: 10/27/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2021-10-27-1-4
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 10/28/2021
Date Tested: 10/27/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2021-10-27-1-5
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/28/2021
Date Tested: 10/28/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
no data
|
Apparent mass of submerged cylinder 1
|
29.29 lb
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
6070 psi
|
Maximum load on cylinder 1
|
171655 lb
|
Maximum load on cylinder 2
|
171400 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
no data0 days
|
Age of specimen in hours
|
16 hours
|
Serial number of delivery ticket, if available
|
no data
|
DIME Test ID: 2021-10-27-1-6
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Verified Date: 10/28/2021
Date Tested: 10/27/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Precast Maximum Curing Temperature
|
158 °F
|
DIME Test ID: 2021-10-27-1-7
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/11/2022
Date Tested: 11/03/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
no data
|
Apparent mass of submerged cylinder 1
|
29.29 lb
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Average diameter of cylinder 3
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Cross sectional area of cylinder 3
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
9550 psi
|
Maximum load on cylinder 1
|
269480 lb
|
Maximum load on cylinder 2
|
270120 lb
|
Maximum load on cylinder 3
|
270230 lb
|
Type of fracture pattern of cylinder 1
|
4
|
Type of fracture pattern of cylinder 2
|
4
|
Type of fracture pattern of cylinder 3
|
4
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
no data0 hours
|
Serial number of delivery ticket, if available
|
no data
|