Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215486 DEA: 040A0204 EFIS: 0400000129
QA Service Level: 1
DIST-CO-RTE-PM: 04-SON-1-15-15.7
Work Description: Construct roadway and bridge with structural concrete and CIDH piling
Location Description: District-County-Route-Post Mile: 04-Son-1-R15.0/R15.7
Contractor Name: BRIDGEWAY CIVIL CONSTRUCTORS, INC.
Contractor Address: 4950 Allison Parkway, # A, Vacaville, CA 95688
Resident Engineer: Fabio La Serna Structure Rep.: Bunma Nou
DIME Sample ID: 2021-10-08-23
TL Number from the TL Form:
Sample Submitted By Organization: RMA Group - Rancho Cordova
Sample Organization Contact: (916) 631-7194
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/08/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/08/2021
The quantity of what the sample constitutes: 100 cy
A brief description of the sample: Concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Shamrock Concrete
The concrete mix design number: SL-4700
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 414606
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: CIDH Pile
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2021-10-08-23-1
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 03/29/2022
Date Tested: 10/08/2021
Submitted By Organization: RMA Group - Rancho Cordova
Organization Address: 3150 Fitzgerald Road,
Organization City: Rancho Cordova
Organization State: CA
Organization Zipcode: 95742
Organization Email: mlowrance@rmacompanies.com
Organization Phone: (916) 631-7194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2021-10-08-23-2
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 03/29/2022
Date Tested: 10/08/2021
Submitted By Organization: RMA Group - Rancho Cordova
Organization Address: 3150 Fitzgerald Road,
Organization City: Rancho Cordova
Organization State: CA
Organization Zipcode: 95742
Organization Email: mlowrance@rmacompanies.com
Organization Phone: (916) 631-7194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2021-10-08-23-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/29/2022
Date Tested: 10/15/2021
Submitted By Organization: RMA Group - Rancho Cordova
Organization Address: 3150 Fitzgerald Road,
Organization City: Rancho Cordova
Organization State: CA
Organization Zipcode: 95742
Organization Email: mlowrance@rmacompanies.com
Organization Phone: (916) 631-7194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
5
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.01 in
|
Average diameter of cylinder 2
|
6.02 in
|
Average diameter of cylinder 3
|
6.01 in
|
Average diameter of cylinder 4
|
6.00 in
|
Average diameter of cylinder 5
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.37 in^2
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
Cross sectional area of cylinder 3
|
28.37 in^2
|
Cross sectional area of cylinder 4
|
28.27 in^2
|
Cross sectional area of cylinder 5
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
5840 psi
|
Maximum load on cylinder 1
|
166780 lb
|
Maximum load on cylinder 2
|
170490 lb
|
Maximum load on cylinder 3
|
164180 lb
|
Maximum load on cylinder 4
|
162670 lb
|
Maximum load on cylinder 5
|
163600 lb
|
Type of fracture pattern of cylinder 1
|
5
|
Type of fracture pattern of cylinder 2
|
3
|
Type of fracture pattern of cylinder 3
|
5
|
Type of fracture pattern of cylinder 4
|
5
|
Type of fracture pattern of cylinder 5
|
5
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Correction factor for cylinder 4
|
1
|
Correction factor for cylinder 5
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
no data0 hours
|
DIME Test ID: 2021-10-08-23-4
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/29/2022
Date Tested: 11/05/2021
Submitted By Organization: RMA Group - Rancho Cordova
Organization Address: 3150 Fitzgerald Road,
Organization City: Rancho Cordova
Organization State: CA
Organization Zipcode: 95742
Organization Email: mlowrance@rmacompanies.com
Organization Phone: (916) 631-7194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
5
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Average diameter of cylinder 3
|
6.00 in
|
Average diameter of cylinder 4
|
6.00 in
|
Average diameter of cylinder 5
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Cross sectional area of cylinder 3
|
28.27 in^2
|
Cross sectional area of cylinder 4
|
28.27 in^2
|
Cross sectional area of cylinder 5
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
7590 psi
|
Maximum load on cylinder 1
|
212310 lb
|
Maximum load on cylinder 2
|
222330 lb
|
Maximum load on cylinder 3
|
218640 lb
|
Maximum load on cylinder 4
|
210210 lb
|
Maximum load on cylinder 5
|
209150 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
5
|
Type of fracture pattern of cylinder 3
|
3
|
Type of fracture pattern of cylinder 4
|
3
|
Type of fracture pattern of cylinder 5
|
5
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Correction factor for cylinder 4
|
1
|
Correction factor for cylinder 5
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data0 hours
|
DIME Test ID: 2021-10-08-23-5
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/29/2022
Date Tested: 11/19/2021
Submitted By Organization: RMA Group - Rancho Cordova
Organization Address: 3150 Fitzgerald Road,
Organization City: Rancho Cordova
Organization State: CA
Organization Zipcode: 95742
Organization Email: mlowrance@rmacompanies.com
Organization Phone: (916) 631-7194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
5
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.01 in
|
Average diameter of cylinder 3
|
6.01 in
|
Average diameter of cylinder 4
|
6.01 in
|
Average diameter of cylinder 5
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
Cross sectional area of cylinder 3
|
28.37 in^2
|
Cross sectional area of cylinder 4
|
28.37 in^2
|
Cross sectional area of cylinder 5
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
7840 psi
|
Maximum load on cylinder 1
|
221350 lb
|
Maximum load on cylinder 2
|
227890 lb
|
Maximum load on cylinder 3
|
221680 lb
|
Maximum load on cylinder 4
|
221950 lb
|
Maximum load on cylinder 5
|
217100 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
5
|
Type of fracture pattern of cylinder 3
|
5
|
Type of fracture pattern of cylinder 4
|
3
|
Type of fracture pattern of cylinder 5
|
5
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Correction factor for cylinder 4
|
1
|
Correction factor for cylinder 5
|
1
|
Age of specimen
|
42 days
|
Age of specimen in hours
|
no data0 hours
|