Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030H10U4 Cty SAC Rte 5 PM 9.7/24.9 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Daniel Tecle |
Date Reported: |
10/19/2021 |
|
Address: |
TL Number: |
281911 |
||
City: |
||||
Project Name: |
||||
Prime Contractor: NOR CAL PAVING TEICHERT/GRANITE |
||||
Sample Taken Date: |
10/01/2021 |
Mix Design: |
Unknown |
|
Contractor: Unknown |
Location : Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.00 | 12.57 | 44639 | 3552.0 | 1 |
2 | 4.00 | 12.57 | 43243 | 3441.0 | 1 |
3 | 4.00 | 12.57 | 43905 | 3494 | 1 |
DIME Test ID: 2021-10-01-5-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3500
Age of specimen: 7 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.00 | 12.57 | 53796 | 4281.0 | 1 |
2 | 4.00 | 12.57 | 43314 | 3447.0 | 1 |
3 | 4.01 | 12.63 | 52519 | 4159 | 1 |
DIME Test ID: 2021-10-01-5-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3960
Age of specimen: 18 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing