Print Report | Back to Sample Detail

Sample Record for 2021-08-23-32

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 44444 DEA: ASCP EFIS: ASCP QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-08-23-32
TL Number from the TL Form:
Sample Submitted By Organization: Marathon Petroleum
Sample Organization Contact: (661) 392-3630
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 08/23/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/23/2021
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: PMA4
From where was the sample collected: Manufacturer
Laboratory sample identification: 082321-PMA4
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bakersfield, CA

Material Information

Performance Grade: PG 64-28M
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Marathon Petroleum
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2021-08-23-32-1
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 09/13/2021
Date Tested: 09/13/2021
Submitted By Organization: Marathon Petroleum
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: gdiaz@marathonpetroleum.com
Organization Phone: (661) 392-3630
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s? Pa-s
Time of test no data HH:MM
Test Temperature no data0 C
Speed no data0 rpm
Spindle size no data in
Torque no data0 %
Viscosity reading #1 (A) no data
Viscosity reading #2 (B) no data
Viscosity reading #3 (C) no data
Average viscosity 0.982 Pa-s

Test 2 of 3

DIME Test ID: 2021-08-23-32-2
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Verified Date: 09/13/2021
Date Tested: 09/13/2021
Submitted By Organization: Marathon Petroleum
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: gdiaz@marathonpetroleum.com
Organization Phone: (661) 392-3630
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg) Celsius and mmHg
Observed Flash Point no data
Ambient Barometric Pressure no data
Cleveland Open-Cup Flash Point in Celsius 305 C

Test 3 of 3

DIME Test ID: 2021-08-23-32-3
Test Method: AASHTO T301-13: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Submitted By Organization: Marathon Petroleum
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: gdiaz@marathonpetroleum.com
Organization Phone: (661) 392-3630