Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215341 DEA: 101J1204 EFIS: 1018000150
QA Service Level: 1
DIST-CO-RTE-PM: 10-MER-33-R0.0/L5.7
Work Description: COLD PLANE ASPHALT CONCRETE AND PLACE HOT MIX ASPHALT.
Location Description: MERCED COUNTY IN AND NEAR DOS PALOS FROM FRESNO COUNTY LINE TO 0.1 MILE NORTH OF EAST JUNCTION ROUTE 152
Contractor Name: CAL VALLEY CONSTRUCTION, INC.
Contractor Address: 5125 N. Gates Ave, Suite 102, Fresno, CA 93722
Resident Engineer: Michael Stewart Structure Rep.: Unknown
DIME Sample ID: 2021-08-03-29
TL Number from the TL Form: 034068
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 08/03/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/11/2021
The quantity of what the sample constitutes: 2 CanS
A brief description of the sample: PG64-16
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Santa Fe Winton
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number: 1
Sublot number: 17
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2021-08-03-29-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/13/2021
Date Tested: 08/18/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
Test Result Compliance:
Additional Comments When Verified:
Determination
|
Unworked Penetration
|
Unworked Penetration
|
34 0.1 mm
|
DIME Test ID: 2021-08-03-29-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/13/2021
Date Tested: 08/18/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
Test Result Compliance:
Additional Comments When Verified:
ASTM Thermometer used?
|
C
|
Softening Point Sample 1
|
68 C
|
Softening Point Sample 2
|
68 C
|
Bath Liquid
|
USP glycerin
|
Minutes Reaction
|
no data
|
DIME Test ID: 2021-08-03-29-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/13/2021
Date Tested: 08/17/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
25 C
|
Final Dial reading (F1)
|
70 mm
|
Ball Penetration (P1)
|
no data0 mm
|
Final Dial reading (F2)
|
68 mm
|
Ball Penetration (P2)
|
1 mm
|
Final Dial reading (F3)
|
69 mm
|
Ball Penetration (P3)
|
no data0 mm
|
Resilience 1
|
30 %
|
Resilience 2
|
33 %
|
Resilience 3
|
31 %
|
Average Resilience
|
31 %
|
Minutes Reaction
|
no data
|