Print Report | Back to Sample Detail

Sample Record for 2021-08-02-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214293 DEA: 060S4604 EFIS: 0615000038 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-99-R0.9/R5.0
Work Description: REPLACE CONCRETE AND ASPHALT PAVEMENT.
Location Description: FRESNO COUNTY IN AND NEAR KINGSBURG AND SELMA FROM ROUTE 99/201 SEPARATION TO 0.3 MILE SOUTH OF SECOND STREET UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 38155 Monroe Street, Indio, CA 92203
Resident Engineer: Mohammad Samimi Structure Rep.: Peter Moua

Sample Information

DIME Sample ID: 2021-08-02-4
TL Number from the TL Form: 057198
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 08/02/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/05/2021
The quantity of what the sample constitutes: 1 of 1 can
A brief description of the sample: Asphalt Binder
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMI - Fresno Central

Material Information

Performance Grade: PG 64-10
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2021-08-02-4-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 08/12/2021
Date Tested: 08/10/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Any material loss from containers during heating process/testing? No
Mass of empty container #1 167.187 grams
Mass of empty container #2 171.497 grams
Mass of container #1 before test (m1i) 202.78 grams
Mass of container #2 before test (m2i) 206.628 grams
Mass of container #1 after test (m1f) 202.7 grams
Mass of container #2 after test (m2f) 206.534 grams
Average mass change -0.246 percent

Test 2 of 5

DIME Test ID: 2021-08-02-4-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/12/2021
Date Tested: 08/10/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications OG
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.00 %
Stress Amplitude 0.161 kPa
Phase Angle (δ) (for the 10 cycles) 89.6 degree
Complex Modulus (G*) (for the 10 measurements) 1.342 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 1.34 kPa

Test 3 of 5

DIME Test ID: 2021-08-02-4-3
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/12/2021
Date Tested: 08/10/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.00 %
Stress Amplitude 0.265 kPa
Phase Angle (δ) (for the 10 cycles) 88.8 degree
Complex Modulus (G*) (for the 10 measurements) 2.653 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 2.65 kPa

Test 4 of 5

DIME Test ID: 2021-08-02-4-4
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/12/2021
Date Tested: 08/11/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter 8 mm
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.00 %
Stress Amplitude 40.361 kPa
Phase Angle (δ) (for the 10 cycles) 66.4 degree
Complex Modulus (G*) (for the 10 measurements) 4034.920 kPa
Test Temperature (Specimen 1) 31.0 C
(G*) x sin(δ)= 3697 kPa

Test 5 of 5

DIME Test ID: 2021-08-02-4-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 08/12/2021
Date Tested: 08/11/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s no data0 C
Maximum test bath temperature at 240 s 0.1 C
Time of test load application no data HH:MM:SS
File name of test data no data
Time beam in bath no data
Time test started no data HH:MM:SS
Flags issued by software during test no data
Correlation coefficient (R²) no data0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 no data0 mN
Deflection at time 0.0 s no data0 µm
Load at time 0.5 s no data0 mN
Deflection at time 0.5 s no data0 µm
Load at 60.0 s 990 mN
Beam deflection 60.0 s 0.523 µm
Measured Stiffness Modulus 60.0 s 153 mPa
Estimated Stiffness Modulus 60.0 s 153 mPa
Difference between stiffness moduli 60.0 s no data
Estimated m-value 60.0 s 0.467