Print Report | Back to Sample Detail

Sample Record for 2014-06-11-8308687

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 7780 DEA: 112T1824 EFIS: 1100020051 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-4.7/5.6
Work Description: REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location Description: SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real #200, Carlsbad, CA 92008
Resident Engineer: Tom Davis Structure Rep.: Anh Ma

Sample Information

DIME Sample ID: 2014-06-11-8308687
TL Number from the TL Form:
Sample Submitted By Organization: Vulcan Materials Company - San Diego
Sample Organization Contact: (619) 572-9564
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/11/2014
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 5 cylinders
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Source
Laboratory sample identification: 2014-06-11-0830
Structure unique identifier: 2014-06-11-0830
Structure name:
The fabricator/manufacturer/facility name: Vulcan Mission Valley

Material Information

The concrete mix design number: 103612F
The truck number from where the sample was collected: 851
The batch plant ticket number from where the sample was collected: 116865
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: RW316 Pilasters
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2014-06-11-8308687-1
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 07/10/2014
Date Tested: 06/11/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: (619) 572-9564
General Comments for this Test:
Test Result Compliance: comply
Additional Comments When Verified:
Temperature 80 F

Test

DIME Test ID: 2014-06-11-8308687-2
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 07/10/2014
Date Tested: 06/11/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: (619) 572-9564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 4 inch

Test

DIME Test ID: 2014-06-11-8308687-3
Test Method: ASTM C231-10: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 07/10/2014
Date Tested: 06/11/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: (619) 572-9564
General Comments for this Test:
Test Result Compliance: comply
Additional Comments When Verified:
Air content 2.5 %

Test

DIME Test ID: 2014-06-11-8308687-4
Test Method: ASTM C138-10b: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 07/10/2014
Date Tested: 06/11/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: (619) 572-9564
General Comments for this Test:
Test Result Compliance: comply
Additional Comments When Verified:
Identification of concrete represented by the sample 2014-6-11-0830
Volume of the measure 0.25 ft^3
Density of concrete 146.4 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content 2.5 %

Test

DIME Test ID: 2014-06-11-8308687-5
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 08/13/2014
Date Tested: 06/18/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: (619) 572-9564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Compressive strength of cylinder (to nearest 10 psi) 2380 psi
Average diameter of cylinder 1 6.00 in
Maximum load on cylinder 1 67360 lb
Type of fracture pattern of cylinder 1 6
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 7 days

Test

DIME Test ID: 2014-06-11-8308687-6
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 08/13/2014
Date Tested: 06/25/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: (619) 572-9564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With density determined from submerged weighing
Density of cylinder no data
Comment on any defect in either specimen or caps (Max 250 Characters) no data

Test

DIME Test ID: 2014-06-11-8308687-7
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 08/13/2014
Date Tested: 07/09/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: (619) 572-9564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Cross sectional area of cylinder 1 no data
Cross sectional area of cylinder 2 no data
Capped in accordance with? ASTM C617/CTM521
Compressive strength (to nearest 10 psi) 3680 psi
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Maximum load on cylinder 1 103000 lb
Maximum load on cylinder 2 104820 lb
Type of fracture pattern of cylinder 1 6
Type of fracture pattern of cylinder 2 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 28 days

Test

DIME Test ID: 2014-06-11-8308687-8
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 08/13/2014
Date Tested: 08/06/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: (619) 572-9564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Compressive strength of cylinder (to nearest 10 psi) 4660 psi
Average diameter of cylinder 1 6.00 in
Maximum load on cylinder 1 131600 lb
Type of fracture pattern of cylinder 1 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 56 days