Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030H4604 Cty PLA Rte 80 PM 2.6/3.1 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Justin Kunert |
Date Reported: |
05/19/2021 |
|
Address: |
TL Number: |
79281 |
||
City: |
||||
Project Name: WIDEN ON-RAMP AND REPLACE BRIDGE. |
||||
Prime Contractor: Myers & Sons Construction |
||||
Sample Taken Date: |
05/12/2021 |
Mix Design: |
C71A4A1 |
|
Contractor: Unknown |
Location : PLACER COUNTY IN ROSEVILLE AT THE ATLANTIC STREET ON RAMP |
|||
Structure unique identifier: |
||||
Structure name: Retaining Walls C and 1 Stem |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.98 | 28.09 | 68735 | 2447.0 | 1 |
2 | 5.98 | 28.09 | 61238 | 2180.0 | 1 |
DIME Test ID: 2021-05-12-12-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 2310
Age of specimen: 1 day
Certified By: Mike Mullins
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.98 | 28.09 | 119320 | 4248.0 | 1 |
2 | 5.98 | 28.09 | 115079 | 4097.0 | 1 |
DIME Test ID: 2021-05-12-12-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4170
Age of specimen: 7 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing