| Unit system used? | US Units |
| Number of specimens | 5 |
| Test performed | With no density determined |
| Average diameter of cylinder 1 | 5.97 in |
| Average diameter of cylinder 2 | 5.97 in |
| Capped in accordance with? | ASTM C617 - Sulfur Mortar Cap |
| Average diameter of cylinder 3 | 5.97 in |
| Average diameter of cylinder 4 | 5.97 in |
| Average diameter of cylinder 5 | 5.97 in |
| Cross sectional area of cylinder 1 | 27.99 in^2 |
| Cross sectional area of cylinder 2 | 27.99 in^2 |
| Cross sectional area of cylinder 3 | 27.99 in^2 |
| Cross sectional area of cylinder 4 | 27.99 in^2 |
| Cross sectional area of cylinder 5 | 27.99 in^2 |
| Compressive strength (to nearest 10 psi) | 840 psi |
| Maximum load on cylinder 1 | 23750 lb |
| Maximum load on cylinder 2 | 23260 lb |
| Maximum load on cylinder 3 | 23530 lb |
| Maximum load on cylinder 4 | 23400 lb |
| Maximum load on cylinder 5 | 23830 lb |
| Compressive strength of cylinder 1 | 848.5 psi |
| Type of fracture pattern of cylinder 1 | 1 |
| Compressive strength of cylinder 2 | 831.0 psi |
| Compressive strength of cylinder 3 | 840.7 psi |
| Compressive strength of cylinder 4 | 836 psi |
| Compressive strength of cylinder 5 | 851.4 psi |
| Type of fracture pattern of cylinder 2 | 1 |
| Type of fracture pattern of cylinder 3 | 1 |
| Type of fracture pattern of cylinder 4 | 1 |
| Type of fracture pattern of cylinder 5 | 1 |
| Comment on any defect in either specimen or caps (Max 250 Characters) | no data |
| Correction factor for cylinder 1 | 1 |
| Correction factor for cylinder 2 | 1 |
| Correction factor for cylinder 3 | 1 |
| Correction factor for cylinder 4 | 1 |
| Correction factor for cylinder 5 | 1 |
| Age of specimen | 5 days |
| Age of specimen in hours | no data0 hours |