Project ID: 44444 DEA: ASCP EFIS: ASCP
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2021-04-05-23
TL Number from the TL Form:
Sample Submitted By Organization: Valero-NuStar PAT - Pittsburg
Sample Organization Contact: (707) 745-7089
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 04/05/2021
Date that the sample was received by the laboratory/organization performing the testing: 04/07/2021
The quantity of what the sample constitutes: 1 of 2 split sample
A brief description of the sample: Asphalt Binder PG 76-22M
From where was the sample collected: Manufacturer
Laboratory sample identification: 7622M-040521
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero Pittsburg
Performance Grade: PG 76-22 M
Modified: Yes
Lot number:
Sublot number:
Tank number: 5001
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Valero-NuStar PAT - Pittsburg CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-04-05-23-1
Test Method: AASHTO R28-16: Accelerated Aging of Asphalt Binder Using a Pressurized Aging Vessel (PAV)
Verified Date: 04/30/2021
Date Tested: 04/08/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample identification
|
7622M040521
|
Aging Test Temperature, nearest 0.5 C
|
110 C
|
Minimum aging temperature recorded
|
110 C
|
Maximum aging temperature recorded
|
110 C
|
Total time during aging that temperature was outside the specified range
|
1 minutes
|
Total aging time (hour)
|
20 hours
|
Total aging time (minute)
|
no data0 minutes
|
The heating temperature
|
110 C
|
DIME Test ID: 2021-04-05-23-2
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Average mass change
|
-0.419 percent
|
DIME Test ID: 2021-04-05-23-3
Test Method: AASHTO T301-13: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
% Elongation Recovery
|
75 %
|
DIME Test ID: 2021-04-05-23-4
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 04/30/2021
Date Tested: 04/09/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Time test started
|
no data HH:MM:SS
|
Flags issued by software during test
|
no data
|
Correlation coefficient (R²)
|
no data0
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
no data0 mN
|
Deflection at time 0.0 s
|
no data0 µm
|
Load at time 0.5 s
|
no data0 mN
|
Deflection at time 0.5 s
|
no data0 µm
|
Load at 60.0 s
|
no data0 mN
|
Beam deflection 60.0 s
|
no data0 µm
|
Measured Stiffness Modulus 60.0 s
|
116.5 mPa
|
Estimated Stiffness Modulus 60.0 s
|
116.5 mPa
|
Difference between stiffness moduli 60.0 s
|
no data
|
Estimated m-value 60.0 s
|
0.348
|
DIME Test ID: 2021-04-05-23-5
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
73.2 degree
|
Dynamic Shear, G*/sin(δ)
|
1.29 kPa
|
DIME Test ID: 2021-04-05-23-6
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test: DSR RTFO also run at 82C to make determine Calculated Delta at 68.5.
Test Result Compliance:
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
67.9 degree
|
Dynamic Shear, G*/sin(δ)
|
2.47 kPa
|
DIME Test ID: 2021-04-05-23-7
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/30/2021
Date Tested: 04/09/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
PAV residue
|
Test Plate Diameter
|
8 mm
|
Phase Angle (δ) (for the 10 cycles)
|
46.0 degree
|
(G*) x sin(δ)=
|
1380 kPa
|
DIME Test ID: 2021-04-05-23-8
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
Time of test
|
12:00 HH:MM
|
Test Temperature
|
135 C
|
Speed
|
20 rpm
|
Spindle size
|
S21 in
|
Torque
|
50 %
|
Viscosity reading #1 (A)
|
1.256 Pa-s
|
Viscosity reading #2 (B)
|
1.26 Pa-s
|
Viscosity reading #3 (C)
|
1.262 Pa-s
|
Average viscosity
|
1.259 Pa-s
|
DIME Test ID: 2021-04-05-23-9
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg)
|
Celsius and mmHg
|
Observed Flash Point
|
306 C
|
Ambient Barometric Pressure
|
752 mmHg
|
Cleveland Open-Cup Flash Point in Celsius
|
306 C
|