Unit system used?
|
US Units
|
Number of specimens
|
6
|
Test performed
|
With no density determined
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 3
|
6.00 in
|
Average diameter of cylinder 4
|
5.99 in
|
Average diameter of cylinder 5
|
6.00 in
|
Average diameter of cylinder 6
|
5.99 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Cross sectional area of cylinder 3
|
28.27 in^2
|
Cross sectional area of cylinder 4
|
28.18 in^2
|
Cross sectional area of cylinder 5
|
28.27 in^2
|
Cross sectional area of cylinder 6
|
28.18 in^2
|
Compressive strength (to nearest 10 psi)
|
1120 psi
|
Maximum load on cylinder 1
|
31370 lb
|
Maximum load on cylinder 2
|
31830 lb
|
Maximum load on cylinder 3
|
30985 lb
|
Maximum load on cylinder 4
|
32080 lb
|
Maximum load on cylinder 5
|
31550 lb
|
Maximum load on cylinder 6
|
31655 lb
|
Compressive strength of cylinder 1
|
1109.7 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
1125.9 psi
|
Compressive strength of cylinder 3
|
1096 psi
|
Compressive strength of cylinder 4
|
1138.4 psi
|
Compressive strength of cylinder 5
|
1116 psi
|
Compressive strength of cylinder 6
|
1123.3 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Type of fracture pattern of cylinder 3
|
2
|
Type of fracture pattern of cylinder 4
|
1
|
Type of fracture pattern of cylinder 5
|
1
|
Type of fracture pattern of cylinder 6
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Correction factor for cylinder 4
|
1
|
Correction factor for cylinder 5
|
1
|
Correction factor for cylinder 6
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
no data0 hours
|