Sample Record for 2021-04-06-27
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214852 DEA: 09380904 EFIS: 0919000059
QA Service Level: 1
DIST-CO-RTE-PM: 09-INY,MNO-178,6-42.9/48.6,26.5/32.3
Work Description: PLACE HMA OVER EXISTING ASPHALT CONCRETE PAVEMENT.
Location Description: INYO AND MONO COUNTIES ON ROUTE 178 FROM ROUTE 127 TO 5.7 MILES EAST OF ROUTE 127 AND ON ROUTE 6 FROM 0.8 MILE NORTH OF ROUTE 120 TO THE NEVADA STATE LINE
Contractor Name: Qualcon Contractors Inc
Contractor Address: 1645 Esmeralda Ave, Minden, NV 89423
Resident Engineer: Steve Tisell Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2021-04-06-27
TL Number from the TL Form:
Sample Submitted By Organization: Ergon Asphalt & Emulsions
Sample Organization Contact: (702) 736-2059
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 04/06/2021
Date that the sample was received by the laboratory/organization performing the testing: 04/06/2021
The quantity of what the sample constitutes: 200 tons
A brief description of the sample: Asphalt Binder Sample
From where was the sample collected: Supplier
Laboratory sample identification: Z3227021
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Ergon Las Vegas
Material Information
Performance Grade: PG 70-10
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Ergon Asphalt & Emulsions Incorporated - Las Vegas NV
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:
Test Results
Test 1 of 10
DIME Test ID: 2021-04-06-27-1
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/13/2021
Date Tested: 04/06/2021
Submitted By Organization: Ergon Asphalt & Emulsions
Organization Address: 3901 West Ponderosa Way,
Organization City: Las Vegas
Organization State: NV
Organization Zipcode: 89118
Organization Email: dan.virkler@ergon.com
Organization Phone: (702) 736-2059
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
86.9 degree
|
Dynamic Shear, G*/sin(δ)
|
1.27 kPa
|
Test 2 of 10
DIME Test ID: 2021-04-06-27-2
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 04/13/2021
Date Tested: 04/06/2021
Submitted By Organization: Ergon Asphalt & Emulsions
Organization Address: 3901 West Ponderosa Way,
Organization City: Las Vegas
Organization State: NV
Organization Zipcode: 89118
Organization Email: dan.virkler@ergon.com
Organization Phone: (702) 736-2059
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
Time of test
|
6:30 HH:MM
|
Test Temperature
|
135 C
|
Speed
|
20 rpm
|
Spindle size
|
21 in
|
Torque
|
24 %
|
Viscosity reading #1 (A)
|
0.6 Pa-s
|
Viscosity reading #2 (B)
|
0.6 Pa-s
|
Viscosity reading #3 (C)
|
0.6 Pa-s
|
Average viscosity
|
0.6 Pa-s
|
Test 3 of 10
DIME Test ID: 2021-04-06-27-3
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Verified Date: 04/13/2021
Date Tested: 04/06/2021
Submitted By Organization: Ergon Asphalt & Emulsions
Organization Address: 3901 West Ponderosa Way,
Organization City: Las Vegas
Organization State: NV
Organization Zipcode: 89118
Organization Email: dan.virkler@ergon.com
Organization Phone: (702) 736-2059
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg)
|
Celsius and mmHg
|
Observed Flash Point
|
332 C
|
Ambient Barometric Pressure
|
703 mmHg
|
Cleveland Open-Cup Flash Point in Celsius
|
334 C
|
Test 4 of 10
DIME Test ID: 2021-04-06-27-4
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 04/13/2021
Date Tested: 04/06/2021
Submitted By Organization: Ergon Asphalt & Emulsions
Organization Address: 3901 West Ponderosa Way,
Organization City: Las Vegas
Organization State: NV
Organization Zipcode: 89118
Organization Email: dan.virkler@ergon.com
Organization Phone: (702) 736-2059
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Average mass change
|
-0.149 percent
|
Test 5 of 10
DIME Test ID: 2021-04-06-27-5
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/13/2021
Date Tested: 04/06/2021
Submitted By Organization: Ergon Asphalt & Emulsions
Organization Address: 3901 West Ponderosa Way,
Organization City: Las Vegas
Organization State: NV
Organization Zipcode: 89118
Organization Email: dan.virkler@ergon.com
Organization Phone: (702) 736-2059
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
85.3 degree
|
Dynamic Shear, G*/sin(δ)
|
2.62 kPa
|
Test 6 of 10
DIME Test ID: 2021-04-06-27-6
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 04/13/2021
Date Tested: 04/06/2021
Submitted By Organization: Ergon Asphalt & Emulsions
Organization Address: 3901 West Ponderosa Way,
Organization City: Las Vegas
Organization State: NV
Organization Zipcode: 89118
Organization Email: dan.virkler@ergon.com
Organization Phone: (702) 736-2059
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is a normal test obtainable?
|
Yes
|
Number of replicates tested
|
One
|
Ductility of test #1 (D1)
|
100 cm
|
Ductility of sample
|
100 cm
|
Test 7 of 10
DIME Test ID: 2021-04-06-27-7
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/13/2021
Date Tested: 04/07/2021
Submitted By Organization: Ergon Asphalt & Emulsions
Organization Address: 3901 West Ponderosa Way,
Organization City: Las Vegas
Organization State: NV
Organization Zipcode: 89118
Organization Email: dan.virkler@ergon.com
Organization Phone: (702) 736-2059
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
PAV residue
|
Test Plate Diameter
|
8 mm
|
Phase Angle (δ) (for the 10 cycles)
|
52.9 degree
|
(G*) x sin(δ)=
|
3220 kPa
|
Test 8 of 10
DIME Test ID: 2021-04-06-27-8
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 04/09/2021
Date Tested: 04/07/2021
Submitted By Organization: Ergon Asphalt & Emulsions
Organization Address: 3901 West Ponderosa Way,
Organization City: Las Vegas
Organization State: NV
Organization Zipcode: 89118
Organization Email: dan.virkler@ergon.com
Organization Phone: (702) 736-2059
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified: Solubility tested by outside AASHTO accredited laboratory. I don't know how to post this test result.
Time test started
|
no data HH:MM:SS
|
Flags issued by software during test
|
no data
|
Correlation coefficient (R²)
|
no data0
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
no data0 mN
|
Deflection at time 0.0 s
|
no data0 µm
|
Load at time 0.5 s
|
no data0 mN
|
Deflection at time 0.5 s
|
no data0 µm
|
Load at 60.0 s
|
no data0 mN
|
Beam deflection 60.0 s
|
no data0 µm
|
Measured Stiffness Modulus 60.0 s
|
96 mPa
|
Estimated Stiffness Modulus 60.0 s
|
no data
|
Difference between stiffness moduli 60.0 s
|
no data
|
Estimated m-value 60.0 s
|
0.392
|
Test 9 of 10
DIME Test ID: 2021-04-06-27-9
Test Method: AASHTO T44-18: Standard Method of Test for Solubility of Bituminous Materials
Submitted By Organization: Ergon Asphalt & Emulsions
Organization Address: 3901 West Ponderosa Way,
Organization City: Las Vegas
Organization State: NV
Organization Zipcode: 89118
Organization Email: dan.virkler@ergon.com
Organization Phone: (702) 736-2059
This test has been superseded on 04/19/2021.
Reason: corrected
Test 10 of 10
DIME Test ID: 2021-04-06-27-10
Test Method: AASHTO T44-18: Standard Method of Test for Solubility of Bituminous Materials
Verified Date: 04/19/2021
Date Tested: 01/04/2021
Submitted By Organization: Ergon Asphalt & Emulsions
Organization Address: 3901 West Ponderosa Way,
Organization City: Las Vegas
Organization State: NV
Organization Zipcode: 89118
Organization Email: dan.virkler@ergon.com
Organization Phone: (702) 736-2059
General Comments for this Test: Tested by outside AASHTO accredited laboratory.
Test Result Compliance:
Additional Comments When Verified:
Was test performed on residue from distillation or evaporation?
|
Evaporation
|
Soluble, percent
|
0.0 %
|
Insoluble, percent
|
0.1 %
|