Sample Information

DIME Sample ID: 2021-03-22-2
TL Number from the TL Form:
Sample Submitted By Organization: Kie-Con, Incorporated - Antioch
Sample Organization Contact: (925) 331-7122
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 03/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 03/23/2021
The quantity of what the sample constitutes: 31 CY
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KIE-CON, INC

Material Information

The concrete mix design number: K4500x
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 109808
Concrete batch plant:
The fabricator/manufacturer designation for the sample: 20-030E 3/22/21
A detailed description of where the material sample was collected: Concrete sample from wheelbarrow
Where the material sample would have been placed if not sampled: Voided Slab
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 5

DIME Test ID: 2021-03-22-2-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/24/2021
Date Tested: 03/24/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C617/CTM521
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 5350 psi
Maximum load on cylinder 1 153110 lb
Maximum load on cylinder 2 149550 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 2 days
Age of specimen in hours 41 hours

Test 2 of 5

DIME Test ID: 2021-03-22-2-2
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 04/19/2021
Date Tested: 04/19/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C617/CTM521
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 9110 psi
Maximum load on cylinder 1 254680 lb
Maximum load on cylinder 2 260320 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours 668 hours

Test 3 of 5

DIME Test ID: 2021-03-22-2-3
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 09/15/2021
Date Tested: 03/22/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 67 F

Test 4 of 5

DIME Test ID: 2021-03-22-2-4
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 09/15/2021
Date Tested: 03/22/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 8.75 inch

Test 5 of 5

DIME Test ID: 2021-03-22-2-5
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 09/15/2021
Date Tested: 03/22/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample 109808
Volume of the measure 0.25 ft^3
Density of concrete 150.8 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content no data