Project ID: 214579 DEA: 010B0904 EFIS: 0100020444
QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-8.2/8.7
Work Description: Panther Creek & Hunter Creek Bridges
Location Description: DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
Contractor Name: Golden State Bridge, Inc
Contractor Address: 3701 Mallard Dr., Benicia, CA 94510
Resident Engineer: Ryan Dunne Structure Rep.: Brian Cinkutis
DIME Sample ID: 2021-03-09-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 03/09/2021
Date that the sample was received by the laboratory/organization performing the testing: 03/11/2021
The quantity of what the sample constitutes: 400 EA
A brief description of the sample: #6 Headed Bar
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier: 01-0085
Structure name: Panther Creek
The fabricator/manufacturer/facility name: HRC Fountain Valley
Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 4104357
Head Manufacturer Lot Number(s): 3 and 6
Rebar Size: #6
Headed Bar Model Name: HRC 150 Heat No 100104524
Size of Head: Full Size - 9x
Head Connection Type: Friction Weld
Head Shape: Circular
Rebar Manufacturer: CMC
Head Manufacturer: HRC
Head Fabricator: HRC
Material Standard Code: ASTM A706
Headed Bar Unique ID:
DIME Test ID: 2021-03-09-6-1
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 03/16/2021
Date Tested: 03/12/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples
|
1
|
Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | 6 | 0.44 | 41626 | 94605 | Ok Necking | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
DIME Test ID: 2021-03-09-6-2
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 03/16/2021
Date Tested: 03/12/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples
|
1
|
Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | 6 | 0.44 | 41526 | 94378 | Ok Necking | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
DIME Test ID: 2021-03-09-6-3
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 03/16/2021
Date Tested: 03/12/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples
|
1
|
Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | 6 | 0.44 | 41559 | 94451 | Ok Necking | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|