Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215039 DEA: 081H4004 EFIS: 0817000031
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-0.4
Work Description: MINOR CONCRETE (MINOR STRUCTURE).
Location Description: SAN BERNARDINO COUNTY IN BARSTOW AT 0.4 MILE EAST OF ROUTE 15
Contractor Name: Pacific Restoration Group Inc
Contractor Address: PO Box 2061, Lake Elsinore, CA 92531-2061
Resident Engineer: Thanh Pham Structure Rep.: Husam Mohd Ankir
DIME Sample ID: 2021-01-05-4
TL Number from the TL Form: 1521
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 01/05/2021
Date that the sample was received by the laboratory/organization performing the testing: 01/11/2021
The quantity of what the sample constitutes: 2 CYLINDERS
A brief description of the sample: CONCRETE CYLINDERS
From where was the sample collected: Other
Laboratory sample identification: 1024-1521
Structure unique identifier:
Structure name: BLAIR DITCH CHANNEL
The fabricator/manufacturer/facility name: ROBERTSONS
The concrete mix design number: SC505B38
The truck number from where the sample was collected: 2
The batch plant ticket number from where the sample was collected: NP
Concrete batch plant: ROBERTSONS
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: UNKNOWN
Where the material sample would have been placed if not sampled: STA 1675 EB I40 BLAIR DITCH CHANNEL
From Lot No.:
Bag Lot No.:
DIME Test ID: 2021-01-05-4-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/04/2021
Date Tested: 01/13/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.02 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.46 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
2160 psi
|
Maximum load on cylinder 1
|
59800 lb
|
Maximum load on cylinder 2
|
62500 lb
|
Compressive strength of cylinder 1
|
2101.2 psi
|
Type of fracture pattern of cylinder 1
|
4
|
Compressive strength of cylinder 2
|
2210.8 psi
|
Type of fracture pattern of cylinder 2
|
4
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
8 days
|
Age of specimen in hours
|
no data
|
DIME Test ID: 2021-01-05-4-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/04/2021
Date Tested: 02/03/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
5.99 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.18 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
3220 psi
|
Maximum load on cylinder 1
|
91250 lb
|
Maximum load on cylinder 2
|
90550 lb
|
Compressive strength of cylinder 1
|
3238.1 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
3203.0 psi
|
Type of fracture pattern of cylinder 2
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
29 days
|
Age of specimen in hours
|
no data
|