Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215313 DEA: 044Q3200 EFIS: 0419000376
QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN-37-11.2/13.7
Work Description: MRN 37 SUSTAINABILITY LONG LEAD PROJECT
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-09-20-12
TL Number from the TL Form: CHR0014
Sample Submitted By Organization: WSP Environment & Infrastructure, Inc.
Sample Organization Contact: (858) 699-0513
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 09/20/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/18/2020
The quantity of what the sample constitutes: bag of soil
A brief description of the sample: native soil
From where was the sample collected: Job Site
Laboratory sample identification: CR20200495
Structure unique identifier: 04-SON-037, PM0.0-3.9
Structure name: Westbound SR37
The fabricator/manufacturer/facility name: Caltrans
The fabricator's/manufacturer's product name for the sample: Soil RW-20-005
The fabricator/manufacturer designation for the sample: Foundation investigation
A detailed description of where the material sample was collected: 15-16.5 feet depth
Where the material sample would have been placed if not sampled:
DIME Test ID: 2020-09-20-12-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 12/01/2020
Date Tested: 11/25/2020
Submitted By Organization: WSP Environment & Infrastructure, Inc.
Organization Address: 690 Walnut Avenue,
Organization City: Vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: aaron.franklin@dot.ca.gov
Organization Phone: (858) 699-0513
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5
|
68 Ohm-cm
|
Minimum soil resistivity at 15.5
|
68 Ohm-cm
|
Minimum soil resistance of the lab measurement
|
54 Ohms
|
Soil sample temperature
|
25.9 C
|
pH of soil
|
6
|
DIME Test ID: 2020-09-20-12-2
Test Method: CTM 417-June 2014: Method of Testing Soils and Waters for Sulfate Content
Verified Date: 12/01/2020
Date Tested: 11/30/2020
Submitted By Organization: WSP Environment & Infrastructure, Inc.
Organization Address: 690 Walnut Avenue,
Organization City: Vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: aaron.franklin@dot.ca.gov
Organization Phone: (858) 699-0513
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type
|
Soils
|
Amount of the analyte in the sample
|
3490
|
DIME Test ID: 2020-09-20-12-3
Test Method: CTM 422-June 2014: Method of Testing Soils and Waters for Chloride Content
Verified Date: 12/01/2020
Date Tested: 11/30/2020
Submitted By Organization: WSP Environment & Infrastructure, Inc.
Organization Address: 690 Walnut Avenue,
Organization City: Vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: aaron.franklin@dot.ca.gov
Organization Phone: (858) 699-0513
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type
|
Soils
|
Amount of the analyte in the sample
|
11259
|