Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213444 DEA: 060Q2804 EFIS: 0613000051
QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-99,178-23.8/R28.4,0.1
Work Description: RECONSTRUCT LANES AND SHOULDERS WITH CRCP, MODIFYING ELECTRICAL SYSTEM
Location Description: KERN COUNTY IN BAKERSFIELD ON ROUTE 99 FROM 0.3 MILE SOUTH OF PALM AVENUE OVERCROSSING TO BEARDSLEY CANAL BRIDGE AND ON ROUTE 178 AT ROUTE 99/178 SEPARATION
Contractor Name: BROSAMER & WALL, INC.
Contractor Address: 1777 Oakland Blvd., Suite 300, Walnut Creek, CA 94596
Resident Engineer: Hugo Camberos Structure Rep.: Luis Melendez
DIME Sample ID: 2020-10-29-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM2 - Type B Elastomeric Joint Seal
Sample Taken Date: 10/29/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/03/2020
The quantity of what the sample constitutes: 1
A brief description of the sample: joint seal
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Watson Bowman
DIME Test ID: 2020-10-29-6-1
Test Method: CTM 673-July 2012: Method of Determining Movement Rating of Type B1 and B2 Preformed Elastomeric Joint Seals
Verified Date: 11/09/2020
Date Tested: 11/04/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
UTM
|
2KIP
|
Temperature
|
72 f
|
Humidity
|
50 %
|
Spec Minimum Uncompressed Width
|
2.78 in
|
Area (5 Times of the Height of Contact Face)
|
13.9675 sqin
|
Half of the Spec Minimum Uncompressed Width
|
no data0 in
|
85 Percent of the Spec Minimum Uncompressed Width
|
2.7935 in
|
3 Times of the Area
|
no data0 sqin
|
4 Times of the Load at W1
|
no data0 lbs
|
W1 (US Units)
|
2.37 in
|
W1 (Metric Units)
|
60.13 millimeters
|
W2 (US Units)
|
1.2 in
|
W2 (Metric Units)
|
30.56 millimeters
|
Satisfactory of MR of (US Units)
|
1.164 in
|
Satisfactory of MR of (Metric Units)
|
29.57 millimeters
|
Optional W1 Measurement 1
|
no data0 in
|
Optional W1 Measurement 2
|
no data0 sqin
|
DIME Test ID: 2020-10-29-6-2
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 11/09/2020
Date Tested: 11/05/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
56
|
Reading #2
|
58
|
Reading #3
|
55
|
Reading #4
|
56
|
Reading #5
|
55
|
Mean
|
56
|
DIME Test ID: 2020-10-29-6-3
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 11/09/2020
Date Tested: 11/05/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
psi
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.082
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2207.07
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.076
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2103.75
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.082
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2142.44
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2142.4 psi
|
DIME Test ID: 2020-10-29-6-4
Test Method: ASTM D471-15a: Standard Test Method for Rubber Property - Effect of Liquids
Verified Date: 11/09/2020
Date Tested: 11/09/2020
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Oil Swell Percentage
|
28 %
|
DIME Test ID: 2020-10-29-6-5
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 11/09/2020
Date Tested: 11/09/2020
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2020-10-29-6-6
Test Method: ASTM D2628-91-re16: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements
Verified Date: 11/09/2020
Date Tested: 11/06/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
High or low tempurature
|
Low
|
Temperature
|
72 f
|
Humidity
|
50 %
|
Temp Recovery (22 hrs at -20F) Size Before (Height of Contact Face )
|
2.75 in
|
Temp Recovery (22 hrs at -20F) Size After (Recovered Contact Face )
|
2.425 in
|
Percent Recovery
|
88 %
|
DIME Test ID: 2020-10-29-6-7
Test Method: ASTM D2628-91-re16: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements
Verified Date: 11/09/2020
Date Tested: 11/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
High or low tempurature
|
High
|
Temperature
|
72 f
|
Humidity
|
50 %
|
Temp Recovery (22 hrs at -20F) Size Before (Height of Contact Face )
|
2.75 in
|
Temp Recovery (22 hrs at -20F) Size After (Recovered Contact Face )
|
2.5815 in
|
Percent Recovery
|
94 %
|