Print Report | Back to Sample Detail

Sample Record for 2020-08-12-38

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215157 DEA: 021H5704 EFIS: 0216000036 QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-299-67.8/77.8
Work Description: BURNEY CAPM - PAVEMENT REHABILITATION
Location Description: BUNCH GRASS LOOKOUT RD TO NAPA LN
Contractor Name: JF Shea Constrcution
Contractor Address: 17400 Clear Creek Road, Redding, CA 96001
Resident Engineer: Kyle Higgins Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-08-12-38
TL Number from the TL Form: 897746
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Informational
Type of Material: Soil
Sample Taken Date: 08/12/2020
Date that the sample was received by the laboratory/organization performing the testing: 08/29/2020
The quantity of what the sample constitutes: not provided
A brief description of the sample: Sand, Silt, Rock
From where was the sample collected: Job Site
Laboratory sample identification: D78588
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Not Provided

Material Information

The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SHA 299 PM 75.83
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 1

DIME Test ID: 2020-08-12-38-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 09/15/2020
Date Tested: 08/29/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 13320 Ohm-cm
Minimum soil resistivity at 15.5 13320 Ohm-cm
Minimum soil resistance of the lab measurement 12000 Ohms
Soil sample temperature 19.9 C
pH of soil 6.93