REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Dan Rechs |
Date Reported: |
08/28/2020 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: ROADWAY EXCAVATION, PLACE HMA & RHMA, & CONSTRUCT DRAINAGE SYSTEMS. |
||||
Prime Contractor: BALDWIN CONTRACTING COMPANY INC. DBA. KNIFE RIVER CONSTRUC TION |
||||
Sample Taken Date: |
08/21/2020 |
Mix Design: |
6316p25 |
|
Contractor: Unknown |
Location : BUTTE COUNTY NEAR OROVILLE FROM 0.2 MILE NORTH OF COX LANE TO 0.1 MILE NORTH OF PALERMO ROAD |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.98 | 28.09 | 100005 | 3561.0 | 1 |
2 | 5.97 | 27.99 | 97541 | 3485.0 | 1 |
DIME Test ID: 2020-08-21-9-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3520
Age of specimen: 7 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |