Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214315 DEA: 081G2104 EFIS: 0815000170
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-210 - 15,210-7.4/9.0, 10.5/12.7
Work Description: Install lighting and ramp metering systems.
Location Description:
Contractor Name: Alfaro Communication
Contractor Address: 15614 South Atlantic Avenue, Compton, CA 90221
Resident Engineer: Lawrance Yaacoub Structure Rep.: Unknown
DIME Sample ID: 2020-08-19-3
TL Number from the TL Form: 1003-819
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/19/2020
Date that the sample was received by the laboratory/organization performing the testing: 08/20/2020
The quantity of what the sample constitutes: 2 Cylinders
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1003-819
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hi-Grade Material
The concrete mix design number: SC590B38
The truck number from where the sample was collected: 2093
The batch plant ticket number from where the sample was collected: 5603242
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled: Route 15 Location 8
From Lot No.:
Bag Lot No.:
DIME Test ID: 2020-08-19-3-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/17/2020
Date Tested: 09/16/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.01 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
Compressive strength (to nearest 10 psi)
|
3610 psi
|
Maximum load on cylinder 1
|
102280 lb
|
Maximum load on cylinder 2
|
102070 lb
|
Compressive strength of cylinder 1
|
3618.0 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
3597.8 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data
|