STATE OF CALIFORNIA - CALIFORNIA STATE TRANSPORTATION AGENCY

Gavin Newsom, Governor


DEPARTMENT OF TRANSPORTATION

DIVISION OF ENGINEERING SERVICES

MATERIALS ENGINEERING AND TESTING SERVICES

Concrete Materials Testing Branch

5900 Folsom Blvd.

Sacramento, CA 95819

916-227-7205

image

Contract # 041J9904 Cty ALA Rte 13 PM 5.2/5.5

Vendor #


REPORT OF LABORATORY TESTING

Resident Engineer:

Rabindra Mukherjee

Date Reported:

06/11/2020

Address:

TL Number:

04-1J9904

City:

Project Name: ALA 13/CC 24 ENHANCE LIGHTING

Prime Contractor: FBD VANGUARD CONSTRUCTION, INC.

Sample Taken Date:

05/14/2020

Mix Design:

550MAC

Contractor: Unknown

Location : ALAMEDA AND CONTRA COSTA COUNTIES AT VARIOUS LOCATIONS

Structure unique identifier:

Structure name:

Location of Pour: Unknown


The following testing has been tested in accordance with:

ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

Cured in accordance with ASTM C511

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
16.0328.561051153681.01
26.0228.461043923668.01

DIME Test ID: 2020-05-14-37-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3670
Age of specimen: 28 days
Certified By: Larry McCrum



Summary of Items Observed and Conversations:

Comments: This report is for the purpose of reporting test results.
Should you require recommendations concerning repairs or remedial efforts please contact the METS representative,
who represents the Materials Engineering and Testing Services for your project.

*Subject to final inspection by the Resident Engineer.