Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 041J9904 Cty ALA Rte 13 PM 5.2/5.5 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Rabindra Mukherjee |
Date Reported: |
06/11/2020 |
|
Address: |
TL Number: |
04-1J9904 |
||
City: |
||||
Project Name: ALA 13/CC 24 ENHANCE LIGHTING |
||||
Prime Contractor: FBD VANGUARD CONSTRUCTION, INC. |
||||
Sample Taken Date: |
05/14/2020 |
Mix Design: |
550MAC |
|
Contractor: Unknown |
Location : ALAMEDA AND CONTRA COSTA COUNTIES AT VARIOUS LOCATIONS |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.03 | 28.56 | 105115 | 3681.0 | 1 |
2 | 6.02 | 28.46 | 104392 | 3668.0 | 1 |
DIME Test ID: 2020-05-14-37-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3670
Age of specimen: 28 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing