Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-05-18-11
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 05/18/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/20/2020
The quantity of what the sample constitutes: 56
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Comments: Unknown
Reel/Coil/Pack Number(s):
Number of Coils: Unknown
Group Number: Unknown
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0541620, S0530919-2, S0509220, S0508120
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire
DIME Test ID: 2020-05-18-11-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/21/2020
Date Tested: 05/21/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0541620 | S379094-2 | 0.22 | 60527 | 56560.9 | 28.2 | 1.63 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|
DIME Test ID: 2020-05-18-11-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/21/2020
Date Tested: 05/21/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0541620 | S379095-2 | 0.22 | 61069 | 56723.3 | 28.2 | 1.73 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|
DIME Test ID: 2020-05-18-11-3
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/21/2020
Date Tested: 05/21/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0530919-2 | S379096-5 | 0.22 | 60163 | 55726.1 | 28.1 | 1.83 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|
DIME Test ID: 2020-05-18-11-4
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/21/2020
Date Tested: 05/21/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0530919-2 | S379098-2 | 0.22 | 59831 | 56416.2 | 28.5 | 1.81 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|
DIME Test ID: 2020-05-18-11-5
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/21/2020
Date Tested: 05/21/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0509220 | S379102-2 | 0.218 | 60155 | 56676.2 | 29 | 1.74 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|
DIME Test ID: 2020-05-18-11-6
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/21/2020
Date Tested: 05/21/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0509220 | S379103-5 | 0.218 | 60507 | 56067.5 | 28.6 | 1.83 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|
DIME Test ID: 2020-05-18-11-7
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/21/2020
Date Tested: 05/21/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0508120 | S379176-1 | 0.218 | 59093 | 55756.5 | 28.9 | 1.85 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|
DIME Test ID: 2020-05-18-11-8
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/21/2020
Date Tested: 05/21/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0508120 | S379176-4 | 0.218 | 59255 | 55955.9 | 28.3 | 1.79 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|