Print Report | Back to Sample Detail

Sample Record for 2020-04-28-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214511 DEA: 010E0004 EFIS: 0113000091 QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-84.4/84.8
Work Description: BRIDGE RAIL REPLACEMENT.
Location Description: HUMBOLDT COUNTY NEAR ARCATA FROM JACOBY CREEK BRIDGE TO GANNON SLOUGH BRIDGE
Contractor Name: Golden State Bridge
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Nathaniel Steen Structure Rep.: Jarred Burrows

Sample Information

DIME Sample ID: 2020-04-28-11
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 04/28/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/08/2020
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 18724-1
Material/Compound/Elastomer ID: na
Samples Representing: 19
Description (size): 1"x16"x16"
Comments: Unknown
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: na

Test Results

Test 1 of 4

DIME Test ID: 2020-04-28-11-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 05/15/2020
Date Tested: 05/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 51
Reading #2 51
Reading #3 50
Reading #4 51
Reading #5 50
Mean 50.6

Test 2 of 4

DIME Test ID: 2020-04-28-11-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 05/15/2020
Date Tested: 05/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.079
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2487.71 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.077
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2340.76 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.078
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2307.33 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2340.8 lbf/in^2

Test 3 of 4

DIME Test ID: 2020-04-28-11-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 05/15/2020
Date Tested: 05/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.085
Sample 1 Tear Strength 216.5
Sample 2 Median Thickness 0.08
Sample 2 Tear Strength 228.5
Sample 3 Median Thickness 0.082
Sample 3 Tear Strength 221.9
Median of the Tear Strength Values 221.9 lb/in

Test 4 of 4

DIME Test ID: 2020-04-28-11-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 05/14/2020
Date Tested: 05/14/2020
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass