Print Report | Back to Sample Detail

Sample Record for 2019-01-29-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 99999 DEA: 0322222 QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-01-29-17
TL Number from the TL Form: C976974
Sample Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Sample Organization Contact: (915) 296-1892
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 01/29/2019
Date that the sample was received by the laboratory/organization performing the testing: 01/29/2019
The quantity of what the sample constitutes: 3 Bags
A brief description of the sample: 1/2 HMA Type A
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Pleasanton

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-01-0010::CALMAT/PLEASANTON
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Stockpile
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 10

DIME Test ID: 2019-01-29-17-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 03/09/2020
Date Tested: 03/09/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 2 in. sieve no data
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 95.2 %
Cumulative percent passing the 3/8 in. sieve 78.4 %
Cumulative percent passing the 1/4 in. sieve 57.8 %
Cumulative percent passing the #4 sieve 48.5 %
Cumulative percent passing the #8 sieve 31.3 %
Cumulative percent passing the #16 sieve 18.8 %
Cumulative percent passing the #30 sieve 12.1 %
Cumulative percent passing the #50 sieve 7.4 %
Cumulative percent passing the #100 sieve 4.2 %
Cumulative percent passing the #200 sieve 2.7 %

Test 2 of 10

DIME Test ID: 2019-01-29-17-2
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 03/09/2020
Date Tested: 03/09/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.619
Average uncompacted voids 46.8 %

Test 3 of 10

DIME Test ID: 2019-01-29-17-3
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 03/09/2020
Date Tested: 03/09/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method 2 - Individual Fracture Determination
Aggregate Size and Fracture Type Coarse 2 Faced and Fine 1 Faced
Weighted average percentage of fractured, coarse, 2 faced particles 99.3 %
Percentage of fractured, fine, 1 faced particles tested 100 %

Test 4 of 10

DIME Test ID: 2019-01-29-17-4
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 03/09/2020
Date Tested: 03/09/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.619
Bulk specific gravity (SSD Basis) 2.665
Apparent specific gravity 2.745
Absorption 1.8 %

Test 5 of 10

DIME Test ID: 2019-01-29-17-5
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 03/09/2020
Date Tested: 03/09/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.657
Absorption 1.4 %

Test 6 of 10

DIME Test ID: 2019-01-29-17-6
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 03/09/2020
Date Tested: 03/09/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Grading designation C
Percent loss after 100 revolutions 4 %
Percent loss after 500 revolutions 21 %

Test 7 of 10

DIME Test ID: 2019-01-29-17-7
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 03/09/2020
Date Tested: 03/09/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sand Equivalent 74

Test 8 of 10

DIME Test ID: 2019-01-29-17-8
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 03/09/2020
Date Tested: 03/09/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method B
Determination By Mass
Dimensional ratio used 5:1
Weighted percentage of particles (by mass) that were flat and elongated 0 %
Weighted percentage of particles (by mass) that were not flat and elongated 100 %

Test 9 of 10

DIME Test ID: 2019-01-29-17-9
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 03/09/2020
Date Tested: 03/09/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Specific Gravity for Sample 1 2.471
Theoretical maximum density at 25°C (77°F) no data

Test 10 of 10

DIME Test ID: 2019-01-29-17-10
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Verified Date: 03/09/2020
Date Tested: 03/09/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Which test procedure(s) is/are used? Procedure A and Procedure B
Was strict temperature control maintained? Yes
What type of water was used? Deminerialized
Durability Index (coarse) 63
Durability Index (fine) 59

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2019-01-29-17-11CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages02/09/2026Not scheduledRyan KesterCT HQ - Sacramento Aggregate Testing Laboratory