Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213943 DEA: 051G5704 EFIS: 0515000049
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-58-0.7/1.9
Work Description: COLD PLANE AC, PLACE RHMA-G AND RECONSTRUCT CURB RAMPS.
Location Description: SAN LUIS OBISPO COUNTY AT SANTA MARGARITA FROM 0.7 MILE EAST OF ROUTE 101/58 SEPARATION TO J STREET
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5335 Debbie Road, Santa Barbara, CA 93111
Resident Engineer: Hassan Iman Structure Rep.: Unknown
DIME Sample ID: 2020-01-01-10
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Quality Control
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 01/01/2020
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 0
A brief description of the sample: ARB
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: National Blending Company
DIME Test ID: 2020-01-01-10-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 01/17/2020
Date Tested: 01/01/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Determination
|
Block Penetration
|
Block Penetration
|
35 0.1 mm
|
Minutes Reaction
|
no data
|
DIME Test ID: 2020-01-01-10-2
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 01/17/2020
Date Tested: 01/01/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
no data
|
Final Dial reading (F1)
|
no data
|
Ball Penetration (P1)
|
no data
|
Final Dial reading (F2)
|
no data
|
Ball Penetration (P2)
|
no data
|
Final Dial reading (F3)
|
no data
|
Ball Penetration (P3)
|
no data
|
Resilience 1
|
no data
|
Resilience 2
|
no data
|
Resilience 3
|
no data
|
Average Resilience
|
37 %
|
Minutes Reaction
|
no data
|
DIME Test ID: 2020-01-01-10-3
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 01/17/2020
Date Tested: 01/01/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
ASTM Thermometer used?
|
C
|
Softening Point Sample 1
|
147 C
|
Softening Point Sample 2
|
no data
|
Bath Liquid
|
freshly boiled distilled water
|
Minutes Reaction
|
no data
|
DIME Test ID: 2020-01-01-10-4
Test Method: ASTM D7741-11ε1: Standard Test Method for Measurement of Apparent Viscosity of Asphalt-Rubber or Other Asphalt Binders by Using a Rotational Handheld Viscometer (Viscosity)
Verified Date: 01/17/2020
Date Tested: 01/01/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Test Temperature
|
60 F
|
Average Viscosity
|
1,900.0
|
Minutes Reaction
|
no data
|