Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 210837 DEA: 080J0804 EFIS: 0800000283 COOP: 081625
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-34.7/51.6
Work Description: (Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location Description: Riverside County and SBD-15-0.0/1.3
Contractor Name: Skanska-Ames, Joint Venture
Contractor Address: 1801 California Avenue, Corona, CA 92881
Resident Engineer: Roy Fisher (reports) Structure Rep.: Roy Fisher
DIME Sample ID: 2019-12-11-52
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 12/11/2019
Date that the sample was received by the laboratory/organization performing the testing: 12/13/2019
The quantity of what the sample constitutes: 4
A brief description of the sample: Splicing Coupler for Prestressing Strand
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: OLDCAST PRECAST PERRIS
Comments: Unknown
Reel/Coil/Pack Number(s): S335009-5
Number of Coils: Unknown
Group Number: Unknown
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): Strand Heat S05491192
Coupler Heat GT12710
Mfg. Lot Number(s): Coupler Heat GT12710
Manufacturer(s): Sumiden Wire and GTI
DIME Test ID: 2019-12-11-52-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/08/2020
Date Tested: 01/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
4
|
| Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | | S0549119-2 | S335009-5 | 0.214 | 60443 | 53787 | 0 | 1.78 | BEWING | | S0549119-2 | S335009-5 | 0.214 | 60249 | 0 | 0 | 0 | BEWING | | S0549119-2 | S335009-5 | 0.214 | 61032 | 54280 | 0 | 1.93 | BEWING | | S0549119-2 | S335009-5 | 0.214 | 58051 | 0 | 0 | 0 | BEWING |
| |
|
UTM
|
120KIP
|
|
Temperature
|
72 f
|
|
Extensometers
|
NA
|