Print Report | Back to Sample Detail

Sample Record for 2019-09-09-18

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214236 DEA: 024H3804 EFIS: 0218000112 MINOR: 02A1831 QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-36-6.6/6.6001
Work Description: Chester MS Infiltration Trench Project
Location Description: Storm Water Improvements in Plumas County about 1.9 miles West of Chester at the Chester Maintenance Station.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-09-09-18
TL Number from the TL Form: 847546
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 09/09/2019
Date that the sample was received by the laboratory/organization performing the testing: 09/10/2019
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: Combined 1/2-inch RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: D78165B
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sierra Cascade Aggregate and Asphalt Products

Material Information

RAP Source: Sierra Cascade
Aggregate Size: Combined
Aggregate Source: Unknown
RAP Stockpile: Static
Stockpile Size (tons): Unknown
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test

DIME Test ID: 2019-09-09-18-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/18/2019
Date Tested: 09/11/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 6.73 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test

DIME Test ID: 2019-09-09-18-2
Test Method: AASHTO T30-15: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 12/18/2019
Date Tested: 09/11/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 98.8 %
Cumulative percent passing the 3/8 in. sieve 93.8 %
Cumulative percent passing the 1/4 in. sieve 82.3 %
Cumulative percent passing the #4 sieve 73.4 %
Cumulative percent passing the #8 sieve 54.1 %
Cumulative percent passing the #16 sieve 40 %
Cumulative percent passing the #30 sieve 29.9 %
Cumulative percent passing the #50 sieve 21.6 %
Cumulative percent passing the #100 sieve 15.2 %
Cumulative percent passing the #200 sieve 11.07 %

Test

DIME Test ID: 2019-09-09-18-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/18/2019
Date Tested: 09/11/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.487
Theoretical maximum density at 25°C (77°F) no data