Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 04014114 Cty ALA Rte 80 PM 2.1 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Behzad Halali |
Date Reported: |
11/01/2019 |
|
Address: |
TL Number: |
00002 |
||
City: |
||||
Project Name: CONSTRUCT MAINTENANCE BUILDING AND PARKING LOT |
||||
Prime Contractor: THOMPSON BUILDERS CORPORATION |
||||
Sample Taken Date: |
10/04/2019 |
Mix Design: |
0000000 |
|
Contractor: Unknown |
Location : IN ALAMEDA COUNTY IN OAKLAND AT THE SAN FRANCISCO-OAKLAND BAY BRIDGE MAINTENANCE YARD |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.35 | 210576 | 7427.7 | 1 |
2 | 6.01 | 28.35 | 210571 | 7427.5 | 1 |
DIME Test ID: 2019-10-04-5-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 7430
Age of specimen: 28 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |