| Unit system used? | US Units |
| Number of specimens | 6 |
| Test performed | With no density determined |
| Cross sectional area of cylinder 1 | 28.46 in^2 |
| Cross sectional area of cylinder 2 | 28.37 in^2 |
| Cross sectional area of cylinder 3 | 28.46 in^2 |
| Capped in accordance with? | ASTM C617/CTM521 |
| Cross sectional area of cylinder 4 | 28.46 in^2 |
| Cross sectional area of cylinder 5 | 28.37 in^2 |
| Cross sectional area of cylinder 6 | 28.46 in^2 |
| Average diameter of cylinder 1 | 6.02 in |
| Average diameter of cylinder 2 | 6.01 in |
| Compressive strength of cylinder 1 | 1392.5 psi |
| Compressive strength of cylinder 2 | 1339.8 psi |
| Average diameter of cylinder 3 | 6.02 in |
| Compressive strength of cylinder 3 | 1431.8 psi |
| Compressive strength (to nearest 10 psi) | 1420 psi |
| Average diameter of cylinder 4 | 6.02 in |
| Compressive strength of cylinder 4 | 1494.7 psi |
| Average diameter of cylinder 5 | 6.01 in |
| Compressive strength of cylinder 5 | 1426.2 psi |
| Average diameter of cylinder 6 | 6.02 in |
| Compressive strength of cylinder 6 | 1457.1 psi |
| Maximum load on cylinder 1 | 39630 lb |
| Maximum load on cylinder 2 | 38010 lb |
| Maximum load on cylinder 3 | 40750 lb |
| Maximum load on cylinder 4 | 42540 lb |
| Maximum load on cylinder 5 | 40460 lb |
| Maximum load on cylinder 6 | 41470 lb |
| Type of fracture pattern of cylinder 1 | 3 |
| Type of fracture pattern of cylinder 2 | 3 |
| Type of fracture pattern of cylinder 3 | 2 |
| Type of fracture pattern of cylinder 4 | 3 |
| Type of fracture pattern of cylinder 5 | 3 |
| Type of fracture pattern of cylinder 6 | 2 |
| Comment on any defect in either specimen or caps (Max 250 Characters) | no data |
| Correction factor for cylinder 1 | 1 |
| Correction factor for cylinder 2 | 1 |
| Correction factor for cylinder 3 | 1 |
| Correction factor for cylinder 4 | 1 |
| Correction factor for cylinder 5 | 1 |
| Correction factor for cylinder 6 | 1 |
| Age of specimen | 7 days |