Print Report | Back to Sample Detail

Sample Record for 2019-09-05-23

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-09-05-23
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 09/05/2019
Date that the sample was received by the laboratory/organization performing the testing: 09/05/2019
The quantity of what the sample constitutes: 1
A brief description of the sample: 3/4 inch RHMA-G SP WMA
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Syar Lake Herman

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-48-0002::LAKE HERMAN QUARRY
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Unknown
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:

Test Results

Test 1 of 9

DIME Test ID: 2019-09-05-23-1
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 10/03/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality AASHTO T-335 Coarse One fractured face(%)
Test Result Compliance:
Additional Comments When Verified:
Method 2 - Individual Fracture Determination
Aggregate Size and Fracture Type Coarse 1 Faced
Weighted average percentage of fractured, coarse, 1 faced particles 98 %

Test 2 of 9

DIME Test ID: 2019-09-05-23-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 10/03/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality AASHTO T-335 Coarse Two fractured face(%)
Test Result Compliance:
Additional Comments When Verified:
Method 2 - Individual Fracture Determination
Aggregate Size and Fracture Type Coarse 2 Faced
Weighted average percentage of fractured, coarse, 2 faced particles 93 %

Test 3 of 9

DIME Test ID: 2019-09-05-23-3
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 10/03/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality AASHTO T-335 Fine One fractured face(%)
Test Result Compliance:
Additional Comments When Verified:
Method 2 - Individual Fracture Determination
Aggregate Size and Fracture Type Fine 1 Faced
Percentage of fractured, fine, 1 faced particles tested 100 %

Test 4 of 9

DIME Test ID: 2019-09-05-23-4
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 10/03/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality AASHTO T-96
Test Result Compliance:
Additional Comments When Verified:
Grading designation B
Percent loss after 100 revolutions 3 %
Percent loss after 500 revolutions 16 %

Test 5 of 9

DIME Test ID: 2019-09-05-23-5
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 10/03/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality AASHTO T-176
Test Result Compliance:
Additional Comments When Verified:
Sand Equivalent 66

Test 6 of 9

DIME Test ID: 2019-09-05-23-6
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 10/03/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality AASHTO T-304 Method A
Test Result Compliance:
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.521
Average uncompacted voids 46.4 %

Test 7 of 9

DIME Test ID: 2019-09-05-23-7
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 10/03/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality ASTM D 4791
Test Result Compliance:
Additional Comments When Verified:
Method A
Determination By Mass
Dimensional ratio used 1:5
Weighted percentage of particles (by mass) that were flat 0 %
Weighted percentage of particles (by mass) that were elongated 0 %
Weighted percentage of particles (by mass) that were both flat and elongated 0.0 %
Weighted percentage of particles (by mass) that were neither flat nor elongated 100 %

Test 8 of 9

DIME Test ID: 2019-09-05-23-8
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 10/03/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality AASHTO T-85
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.648
Absorption 2.9 %

Test 9 of 9

DIME Test ID: 2019-09-05-23-9
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 10/03/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality AASHTO T-84
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.521
Bulk specific gravity (SSD Basis) 2.643
Apparent specific gravity 2.871
Absorption 4.8 %