Sample Record for 2019-07-18-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213520 DEA: 120M9004 EFIS: 1213000017
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-22-R5.6/R10.9
Work Description: RECHANNELIZE TO ENHANCE TRAFFIC FLOW
Location Description: ORANGE COUNTY AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF BROOKHURST STREET UNDERCROSSING IN GARDEN GROVE TO BEDFORD ROAD OVERCROSSING IN ORANGE
Contractor Name: POWELL CONSTRUCTORS, INC.
Contractor Address: 8555 Banana Avenue, Fontana, CA 92335
Resident Engineer: Adrian Wu Structure Rep.: Theodore Pham
Sample Information
DIME Sample ID: 2019-07-18-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/18/2019
Date that the sample was received by the laboratory/organization performing the testing: 07/18/2019
The quantity of what the sample constitutes: 12
A brief description of the sample: Anchor bolt assemblies
From where was the sample collected: Source
Laboratory sample identification: B24-018-19
Structure unique identifier: 12-0M9004
Structure name:
The fabricator/manufacturer/facility name: EDSCO Fasteners
Material Information
Rocap Number(s): NONE
Heat Number(s): 3084898
Nut Mfg. Lot Number(s): 188194
Washer Mfg. Lot Number(s): 176419
Bolt Specification: F1554GR55
Bolt Length(s): 7'
Nut Specification: A194GR2H
Washer Specification: F193
Finish: Hot Dip Gal
Diameter/Size: 2"
Bolt Mfg. Lot Number: 3084898
Rocap Test Requirement(s): NONE
Lubricant Requirements(s): ASTM
Test Results
Test 1 of 9
DIME Test ID: 2019-07-18-1-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 07/25/2019
Date Tested: 07/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | 3084898 | 0.499 | 0.196 | 68099 | 93250 | 25.6 | Steve |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
Test 2 of 9
DIME Test ID: 2019-07-18-1-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 07/25/2019
Date Tested: 07/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 3084898 | 0.499 | 0.196 | 69783 | 93560 | 25.7 | Steve |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
Test 3 of 9
DIME Test ID: 2019-07-18-1-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/25/2019
Date Tested: 07/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
3084898
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW
|
Size
|
2 in
|
Bolt Length
|
84 in
|
Gage Type
|
Pass
|
Test 4 of 9
DIME Test ID: 2019-07-18-1-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 07/25/2019
Date Tested: 07/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH D/N 2H
|
Size
|
2 in
|
Gage Type
|
Pass
|
Test 5 of 9
DIME Test ID: 2019-07-18-1-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/25/2019
Date Tested: 07/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
3084898
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW
|
Size
|
2 in
|
Bolt Length
|
84 in
|
Measurement Average
|
7.86 mils
|
Test 6 of 9
DIME Test ID: 2019-07-18-1-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/25/2019
Date Tested: 07/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH D/N 2H
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.52 mils
|
Test 7 of 9
DIME Test ID: 2019-07-18-1-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/25/2019
Date Tested: 07/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
308878
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.13 mils
|
Test 8 of 9
DIME Test ID: 2019-07-18-1-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/25/2019
Date Tested: 07/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH D/N 2H
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
28.97
|
Spacing
|
Ok
|
Test 9 of 9
DIME Test ID: 2019-07-18-1-9
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/25/2019
Date Tested: 07/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
308878
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
35.6
|
Spacing
|
Ok
|