Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 04013584 Cty SF Rte 80 PM 8.0/8.3,0.9/1.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Brian Boal |
Date Reported: |
06/14/2019 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: Pier Retention |
||||
Prime Contractor: Kiewit/Manson, AJV |
||||
Sample Taken Date: |
05/17/2019 |
Mix Design: |
0000000000 |
|
Contractor: Unknown |
Location : In San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.35 | 223737 | 7892.0 | 1 |
2 | 6.01 | 28.35 | 225034 | 7937.7 | 1 |
DIME Test ID: 2019-05-17-15-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 7910
Age of specimen: 28 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing