Sample Record for 2019-05-01-2
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 211848 DEA: 112T2174 EFIS: 1116000131
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-R37.4 - R46.5
Work Description: (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location Description: IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
Contractor Name: Flatiron-Skanska-Stacy and Witbeck, a Joint Venture
Contractor Address: 1770 La Costa Meadows Drive, San Marcos, CA 92078
Resident Engineer: Steve McMillan Structure Rep.: Phong Le
Sample Information
DIME Sample ID: 2019-05-01-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 05/01/2019
Date that the sample was received by the laboratory/organization performing the testing: 05/01/2019
The quantity of what the sample constitutes: 307 by 50 foot long bars
A brief description of the sample: 8 ASTM A615 Grade 75 ASTM A934 Purple Epoxy Coated Threaded WFE Bars w/ nuts
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form San Diego
Material Information
Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: 8
Nut Specification for Threaded Bar: ASTM A108
System Manufacturer: Williams Form Engineering
Epoxy Coating Color: Purple
Threaded Bar Application: Soil Nail
Coating Standards: ASTM A934 epoxy
Bar Heat Number(s): 100894430
Nut Heat Number(s): 8297103
Bar Lot Number: 10089443020
Nut Lot Number: 8S9D
Coupler Heat Number(s): NA
Coupler Grade: NA
Test Results
Test 1 of 4
DIME Test ID: 2019-05-01-2-1
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 05/10/2019
Date Tested: 05/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar 1&2
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL
|
10 mils
|
Upper spec. limit USL
|
15 mils
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
First Bar Mean
|
12.4 mils
|
Second Bar Mean
|
12.68 mils
|
Total mean value
|
12.54 mils
|
Test 2 of 4
DIME Test ID: 2019-05-01-2-2
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 05/10/2019
Date Tested: 05/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar 3&4
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL
|
10 mils
|
Upper spec. limit USL
|
15 mils
|
Bar # for First Bar
|
3
|
Bar # for Second Bar
|
4
|
First Bar Mean
|
11.45
|
Second Bar Mean
|
12.24
|
Total mean value
|
11.84
|
Test 3 of 4
DIME Test ID: 2019-05-01-2-3
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 05/10/2019
Date Tested: 05/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
16
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|
Test 4 of 4
DIME Test ID: 2019-05-01-2-4
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 05/10/2019
Date Tested: 05/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL
|
10 mils
|
Upper spec. limit USL
|
15 mils
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
First Bar Mean
|
10.37
|
Second Bar Mean
|
12.68
|
Total mean value
|
11.53
|