Print Report | Back to Sample Detail | Back to Aggregate Report

Sample Record for 2018-02-27-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-02-27-26
TL Number from the TL Form: 18-J-006
Sample Submitted By Organization: Sierra Pacific Materials
Sample Organization Contact: (805) 423-2327
Type of Sample: Quality Control
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 02/27/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/27/2018
The quantity of what the sample constitutes: JMF Renewal
A brief description of the sample: 1/2 HMA
From where was the sample collected: Manufacturer
Laboratory sample identification: 18-J-006
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SPM-Templeton

Material Information

RAP Source: Stockpile
Aggregate Size: 1/2
Aggregate Source: Unknown
RAP Stockpile:
Stockpile Size (tons): Unknown
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test

DIME Test ID: 2018-02-27-26-1
Test Method: CTM 202-Oct 2014: Method of Test for Determining Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 02/24/2019
Date Tested: 03/22/2018
Submitted By Organization: Sierra Pacific Materials
Organization Address: 45315 Lost Hills Road,
Organization City: Coalinga
Organization State: CA
Organization Zipcode: 93210
Organization Email: mdavis@papichconstruction.com
Organization Phone: (805) 423-2327
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What size aggregate is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 99.1 %
Cumulative percent passing the 3/8 in. sieve 92.8 %
Cumulative percent passing the #4 sieve 75.9 %
Cumulative percent passing the #8 sieve 62.3 %
Cumulative percent passing the #16 sieve 49.6 %
Cumulative percent passing the #30 sieve 36.2 %
Cumulative percent passing the #50 sieve 23.4 %
Cumulative percent passing the #100 sieve 14.1 %
Cumulative percent passing the #200 sieve 9.5 %

Test

DIME Test ID: 2018-02-27-26-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 02/24/2019
Date Tested: 03/22/2018
Submitted By Organization: Sierra Pacific Materials
Organization Address: 45315 Lost Hills Road,
Organization City: Coalinga
Organization State: CA
Organization Zipcode: 93210
Organization Email: mdavis@papichconstruction.com
Organization Phone: (805) 423-2327
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.8 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test

DIME Test ID: 2018-02-27-26-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 02/24/2019
Date Tested: 03/22/2018
Submitted By Organization: Sierra Pacific Materials
Organization Address: 45315 Lost Hills Road,
Organization City: Coalinga
Organization State: CA
Organization Zipcode: 93210
Organization Email: mdavis@papichconstruction.com
Organization Phone: (805) 423-2327
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.483
Theoretical maximum density at 25°C (77°F) no data