Sample Record for 2019-02-12-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210837 DEA: 080J0804 EFIS: 0800000283 COOP: 081625 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-34.7/51.6
Work Description: (Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location Description: Riverside County and SBD-15-0.0/1.3
Contractor Name: Skanska-Ames, Joint Venture
Contractor Address: 1801 California Avenue, Corona, CA 92881
Resident Engineer: Roy Fisher (reports) Structure Rep.: Roy Fisher

Sample Information

DIME Sample ID: 2019-02-12-2
TL Number from the TL Form: 0212
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 02/12/2019
Date that the sample was received by the laboratory/organization performing the testing: 02/14/2019
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 974-0212
Structure unique identifier: lcb 0212 7 days break
Structure name: lcb 0212 7 days break
The fabricator/manufacturer/facility name: security paving

Material Information

The concrete mix design number: g3-18-LBC-110
The truck number from where the sample was collected: na
The batch plant ticket number from where the sample was collected: na
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: SECURITY PAVING
A detailed description of where the material sample was collected: na
Where the material sample would have been placed if not sampled: lcb 0212 7 days break
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2019-02-12-2-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 02/22/2019
Date Tested: 02/19/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 4
Test performed With no density determined
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.37 in^2
Cross sectional area of cylinder 3 28.27 in^2
Capped in accordance with? ASTM C617/CTM521
Cross sectional area of cylinder 4 28.27 in^2
Average diameter of cylinder 1 6.00 in
Compressive strength (to nearest 10 psi) 430 psi
Average diameter of cylinder 2 6.01 in
Compressive strength of cylinder 1 423.8 psi
Compressive strength of cylinder 2 418.4 psi
Average diameter of cylinder 3 6.00 in
Compressive strength of cylinder 3 473.6 psi
Average diameter of cylinder 4 6.00 in
Compressive strength of cylinder 4 423.4 psi
Maximum load on cylinder 1 11980 lb
Maximum load on cylinder 2 11870 lb
Maximum load on cylinder 3 13390 lb
Maximum load on cylinder 4 11970 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Type of fracture pattern of cylinder 4 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Correction factor for cylinder 4 1
Age of specimen 7 days