Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 210837 DEA: 080J0804 EFIS: 0800000283 COOP: 081625
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-34.7/51.6
Work Description: (Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location Description: Riverside County and SBD-15-0.0/1.3
Contractor Name: Skanska-Ames, Joint Venture
Contractor Address: 1801 California Avenue, Corona, CA 92881
Resident Engineer: Roy Fisher (reports) Structure Rep.: Roy Fisher
DIME Sample ID: 2019-01-24-5
TL Number from the TL Form: 26
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 01/24/2019
Date that the sample was received by the laboratory/organization performing the testing: 01/28/2019
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 974-26
Structure unique identifier: 3rd street approach slab
Structure name: 3rd street approach slab
The fabricator/manufacturer/facility name: Robertson
The concrete mix design number: SC675B38
The truck number from where the sample was collected: 1942
The batch plant ticket number from where the sample was collected: 4111710
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: SKANSKA AMES
A detailed description of where the material sample was collected: load 11
Where the material sample would have been placed if not sampled: 3rd street approach slab
From Lot No.: Unknown
Bag Lot No.: Unknown
DIME Test ID: 2019-01-24-5-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521 Cured in accordance with ASTM C511
Verified Date: 02/08/2019
Date Tested: 02/07/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
28.37 in^2
|
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
|
Capped in accordance with?
|
ASTM C617/CTM521
|
|
Compressive strength (to nearest 10 psi)
|
3940 psi
|
|
Average diameter of cylinder 1
|
6.01 in
|
|
Average diameter of cylinder 2
|
6.02 in
|
|
Compressive strength of cylinder 1
|
4089.2 psi
|
|
Compressive strength of cylinder 2
|
3789.9 psi
|
|
Maximum load on cylinder 1
|
116010 lb
|
|
Maximum load on cylinder 2
|
107860 lb
|
|
Type of fracture pattern of cylinder 1
|
4
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
14 days
|
DIME Test ID: 2019-01-24-5-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521 Cured in accordance with ASTM C511
Verified Date: 02/15/2019
Date Tested: 02/14/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
28.56 in^2
|
|
Cross sectional area of cylinder 2
|
28.56 in^2
|
|
Capped in accordance with?
|
ASTM C617/CTM521
|
|
Compressive strength (to nearest 10 psi)
|
4250 psi
|
|
Average diameter of cylinder 1
|
6.03 in
|
|
Average diameter of cylinder 2
|
6.03 in
|
|
Compressive strength of cylinder 1
|
4208.3 psi
|
|
Compressive strength of cylinder 2
|
4293.1 psi
|
|
Maximum load on cylinder 1
|
120190 lb
|
|
Maximum load on cylinder 2
|
122610 lb
|
|
Type of fracture pattern of cylinder 1
|
1
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
21 days
|
DIME Test ID: 2019-01-24-5-3
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521 Cured in accordance with ASTM C511
Verified Date: 02/22/2019
Date Tested: 02/21/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
28.46 in^2
|
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
|
Capped in accordance with?
|
ASTM C617/CTM521
|
|
Compressive strength (to nearest 10 psi)
|
4240 psi
|
|
Average diameter of cylinder 1
|
6.02 in
|
|
Average diameter of cylinder 2
|
6.02 in
|
|
Compressive strength of cylinder 1
|
4238.2 psi
|
|
Compressive strength of cylinder 2
|
4232.3 psi
|
|
Maximum load on cylinder 1
|
120620 lb
|
|
Maximum load on cylinder 2
|
120450 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
28 days
|