Print Report | Back to Sample Detail

Sample Record for 2019-01-03-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-01-03-5
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 01/03/2019
Date that the sample was received by the laboratory/organization performing the testing: 01/03/2019
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Slag Cement
From where was the sample collected: Source
Laboratory sample identification: CM185854
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: LEHIGH

Material Information

Brand: Lehigh
Mill: Japan
Type of Cementitious Material: Slag Cement

Test Results

Test 1 of 6

DIME Test ID: 2019-01-03-5-3
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 01/07/2021
Date Tested: 04/22/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 day test -- Specimen 2 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? yes
Age of specimen 7 days
The amount of flow 110 %
The amount of water used 46.8 %
Compressive strength of 1st specimen 4150 psi
Compressive strength of 2nd specimen 4591 psi
Compressive strength of 3rd specimen 4157 psi
Average Compressive strength (to nearest 10 psi) 4150 psi
Average Compressive strength (to nearest 10 psi) control group 4050 psi
Strength Activity Index of Portland Cement per ASTM C109 102 %

Test 2 of 6

DIME Test ID: 2019-01-03-5-4
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 01/07/2021
Date Tested: 05/13/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 day test -- Specimen 1 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? yes
Age of specimen 28 days
The amount of flow 110 %
The amount of water used 46.8 %
Compressive strength of 1st specimen 6920 psi
Compressive strength of 2nd specimen 6501 psi
Compressive strength of 3rd specimen 6088 psi
Average Compressive strength (to nearest 10 psi) 6290 psi
Average Compressive strength (to nearest 10 psi) control group 5020 psi
Strength Activity Index of Portland Cement per ASTM C109 125 %

Test 3 of 6

DIME Test ID: 2019-01-03-5-5
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 01/07/2021
Date Tested: 03/28/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity 3.15
Water Content 234 mL
The amount of flow (In percent) 94 %
The amount of water used (In percent) 66.86 %
Net Weight of Sample 855.2 grams
Air Content 6 %

Test 4 of 6

DIME Test ID: 2019-01-03-5-7
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 01/07/2021
Date Tested: 06/25/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method Used Test Method A
Test Time 120 seconds
Fineness 4690 cm^2/g

Test 5 of 6

DIME Test ID: 2019-01-03-5-8
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 01/07/2021
Date Tested: 04/30/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Corrected residue, % (Rc) no data0 %
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325) 100 %

Test 6 of 6

DIME Test ID: 2019-01-03-5-9
Test Method: ASTM C188-15: Standard Test Method for Density of Hydraulic Cement
Verified Date: 01/07/2021
Date Tested: 06/12/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Density of hydraulic cement 2.962 g/cm^3