Sample Record for 2018-10-02-28
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: YYZ
Contractor Address: 1234 address, Sacramento, CA 95824
Resident Engineer: RE_first RE_last Structure Rep.: SR_First SR_Last
Sample Information
DIME Sample ID: 2018-10-02-28
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Materials Management Branch Field Office
Sample Organization Contact: (562) 500-5861
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 10/02/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/12/2018
The quantity of what the sample constitutes: 1
A brief description of the sample: 1
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: aaa
Material Information
Source Identification (SMARA, name of Pit or Job Site): 1111
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: aa
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/8 inch
The concrete mix design number: Unknown
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 1
DIME Test ID: 2018-10-02-28-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 10/19/2018
Date Tested: 10/04/2018
Submitted By Organization: CT HQ - Sacramento Materials Management Branch Field Office
Organization Address: 5900 Folsom Boulevard, MS 5,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brett.soldano@dot.ca.gov
Organization Phone: (562) 500-5861
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested?
|
HMA Gradation
|
Cumulative percent passing the 1 1/2 in. sieve
|
no data0 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
79.4 %
|
Cumulative percent passing the 3/8 in. sieve
|
29.4 %
|
Cumulative percent passing the 1/4 in. sieve
|
no data0 %
|
Cumulative percent passing the #4 sieve
|
1 %
|
Cumulative percent passing the #8 sieve
|
1 %
|
Cumulative percent passing the #16 sieve
|
1 %
|
Cumulative percent passing the #30 sieve
|
1 %
|
Cumulative percent passing the #50 sieve
|
1 %
|
Cumulative percent passing the #100 sieve
|
1 %
|
Cumulative percent passing the #200 sieve
|
0.9 %
|