Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212956 DEA: 080R3404 EFIS: 0812000072
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-38-30.9
Work Description: BRIDGE REHABILITATION AND UPGRADE BRIDGE RAILING TO STANDARDS
Location Description: SAN BERNARDINO COUNTY NEAR ANGELUS OAKS AT SANTA ANA RIVER BRIDGERAM
Contractor Name: RSB GROUP, INC.
Contractor Address: 20331 Lake Forest Dr, Lake Forest, CA 92630
Resident Engineer: Ken Tran Structure Rep.: Sylvia Stracner
DIME Sample ID: 2018-10-02-4
TL Number from the TL Form: 10021
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/02/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/04/2018
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 988-10021
Structure unique identifier: bridge overhang and ST 70 Barrier
Structure name: bridge overhang and ST 70 Barrier
The fabricator/manufacturer/facility name: Robertsons LUCERNE
The concrete mix design number: rrm18066
The truck number from where the sample was collected: 1438
The batch plant ticket number from where the sample was collected: 38202285
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: rsb gruop
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled: bridge overhang and ST 70 Barrier
From Lot No.: Unknown
Bag Lot No.: Unknown
DIME Test ID: 2018-10-02-4-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521 Cured in accordance with ASTM C511
Verified Date: 10/31/2018
Date Tested: 10/30/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
28.56 in^2
|
|
Cross sectional area of cylinder 2
|
28.56 in^2
|
|
Capped in accordance with?
|
ASTM C617/CTM521
|
|
Compressive strength (to nearest 10 psi)
|
4250 psi
|
|
Average diameter of cylinder 1
|
6.03 in
|
|
Average diameter of cylinder 2
|
6.03 in
|
|
Compressive strength of cylinder 1
|
4214.3 psi
|
|
Compressive strength of cylinder 2
|
4279.8 psi
|
|
Maximum load on cylinder 1
|
120360 lb
|
|
Maximum load on cylinder 2
|
122230 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
28 days
|